3OM-1343-008_w.pdf - 第201页

5-16 AKFEDT -ID (1) Feeder No. Shown are the feeder Nos. (2) T otal Components Each text box shows the total number of picked components (number of pickup actions) for each individual feeders. (3) A: comp. Missing Each t…

100%1 / 343
5-15
AKFEDT-ID
2.2 Handling Errors Per Feeder
When the "Handling Err. Per Fdr" tab is pressed in the "Management Data"
window, the following tab sheet appears inside the window.
Fig. 3E8 "Handling Err. Per Fdr" Tab Sheet
Fig. 3E8-1 "Management Data (Chart)" Window ("Handling Errors per Feeder" Window)
Note
The displayed tab sheet will look different, depending on which option is
selected.
The "Handling Err. Per Fdr" tab sheet is divided further into several tabs and
each tab sheet shows the handling errors per feeder on each individual feeder
bases.
When each tab is pressed, the corresponding tab sheet appears.
0607-003
2.2 Handling Errors Per Feeder
5-16
AKFEDT-ID
(1) Feeder No.
Shown are the feeder Nos.
(2) Total Components
Each text box shows the total number of picked components (number of
pickup actions) for each individual feeders.
(3) A: comp. Missing
Each text box shows the total number of missing components detected
by the linear measure detection sensor for each individual feeders.
(4) B: comp. Missing
Each text box shows the total number of missing components detected
through recognition operation for each individual feeders.
(5) C: comp. Vertical
Each text box shows the total number of vertical component errors
detected by the linear measure detection sensor for each individual
feeders.
(6) D: comp. Recog.
Each text box shows the total number of errors detected through
recognition operation for each individual feeders.
(7) E: comp. Thick
Each text box shows the total number of errors in component thickness
detected by the linear measure detection sensor for each individual
feeders.
(8) F: pick-up Diff
Each text box shows the total number of pickup difference errors
detected in the recognition process for each individual feeders.
(9) G: comp. Posture
Each text box shows the total number of reversed component and
polarity judgment errors detected in the recognition process for each
individual feeders.
(10) Total Errors
Each text box shows the total number of errors detected in (3) through
(9).
0607-003
2.2 Handling Errors Per Feeder
5-17
AKFEDT-ID
(11) Rate of Error (%)
Each text box shows the percentage of the total number of errors per the
number of picked components.
(12) Shrtg. of Comp.
Each text box shows the total number of component shortage errors
detected for each individual feeders.
Note
When one of the above buttons is pressed, the feeder No. with the biggest
parameter under the selected button is displayed in the rst line and feeder
Nos. having the subsequent (second, third, fourth, ...) biggest parameters
follow.
That is, parameters are re-arranged in order of error counts, making it easy
to analyze and improve production rate.
When the [Feeder No.] button is pressed, the feeder Nos. are re-arranged
in their initial order (order of slot Nos.).
0607-003
2.2 Handling Errors Per Feeder