5-29 AKFEDT -ID PCB transfer time Shown is the period of time during which Conveyor NL, NR, NA, NB, and NC are being activated. PCB wait Input wait Shown is the period of time during which the machine was completely in t…

5-28
AKFEDT-ID
(9) Waste components
Shown is the total number of components that were picked up but not
placed.
Note
The indicated number of components represents the components that
were not placed due to a vertical component error (sensor), a component
recognition error, a component thickness error, interrupted production, the
detection (Unit PCB BBR Mode: Option) of a defective unit PCB., etc.
(10) Warm-up run (Test Mode)
The data of the warm-up run (dry cycle) is counted.
PCB counter
The number of PCBs is counted when the machine is operated under
the following condition.
•
"Test Mode" is enabled in the "OPERATION MODE" window.
•
"PCB Transfer Dsbl." Check Box Checked
(State in which no PCB is put in and out)
Not Picked Counts
The number of non-handling/non-placed actions is counted when the
machine is operated under the following condition.
•
"Test Mode" is enabled in the "OPERATION MODE" window.
•
The "Handling/Place Disabled" or the "Vacuum/Blower Disabled"
check box is ticked.
(11) PCB process time
Shown is the total of the time required to fi nish a PCB.
(12) Power on time
Shown is the period of time during which the control power of the
machine was working.
Note
Example: 10:03'50" (10 hours, 3 minutes, and 50 seconds)
Auto run time
Shown is the period of time during which the machine was running
automatically.
When a particular pattern program is set several times as current one,
the sum total is computed.
Placement time
Shown is the time required to fi nish a PCB (from the fi rst to the last
component placement on one product PCB).
The essential component placement time is summed up. While
the machine is set in the "STOP" or the "PAUSE" mode or a step
operation is performed, the time is not measured.
This is used to calculate the average placement tact time per
component.
0607-003
3.2 Machine Performance Data

5-29
AKFEDT-ID
PCB transfer time
Shown is the period of time during which Conveyor NL, NR, NA,
NB, and NC are being activated.
PCB wait
Input wait
Shown is the period of time during which the machine was
completely in the waiting mode (the machine was waiting for a
PCB to be loaded from the input machine).
Output wait
Shown is the period of time during which the machine was
completely in the waiting mode (the machine was waiting for a
PCB to be unloaded to the output machine).
PEC/BBR
Shown is the period of time during which the machine is taking PEC
recognition and BBR detection actions.
Counted is the period of time during which the X/Y beam starts
moving and the PEC recognition and BBR detection are completed.
Others
Shown is the period of time during which the machine takes actions
other than the above-described ones.
Note
Included are the periods of time during which the X/Y beam takes
actions before component placement, the X/Y beam returns after
component placement, etc.
Stop time
Shown is the period of time during which component placement
operation was interrupted for component replenishment, etc.
Error stop
Error alarm
Shown is the period of time during which an alarm (light tower
ON) is issued.
Recovery
Shown is the time between error cancellation and restart of
machine operation.
Feeder Reload
Shown is the time during which components were replenished.
Others
Shown is the period of time during which the machine has performed
the setup, program change, idling operations, etc.
3.2 Machine Performance Data
0607-004

5-30
AKFEDT-ID
(13) Maintenance time
Shown is the period of time during which the [SETUP] button on the
main menu bar is pressed.
(14) Warm-up run (Test Mode) time
The running time is counted when the machine is operated under the
following condition.
•
"Test Mode" is enabled in the "OPERATION MODE" window.
•
The "PCB Transfer Dsbl." check box is ticked.
(State in which no PCB is put in and out)
(15) Test mode time
Shown is the period of time during which test run was performed
according to the test mode parameters.
(16) Total handling errors/Total components
Shown are the total number of pickup errors, the total number of
components to be picked up, and the percentage of picked components
per total number of pickup errors.
A: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected by the
linear measure detection sensor and the percentage of errors per total
number of pickup errors.
B: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected in the
recognition process and the percentage of errors per total number of
pickup errors.
C: comp. vertical (% of Total handling errors)
Shown are the number of vertical component errors detected by
the linear measure detection sensor and the percentage of vertical
component errors per total number of pickup errors.
D: comp. recog (% of Total handling errors)
Shown are the number of errors detected in the recognition process and
the percentage of errors per total number of pickup errors.
E: comp. thick (% of Total handling errors)
Shown are the number of component thickness errors detected by the
linear measure detection sensor and the percentage of errors per total
number of pickup errors.
3.2 Machine Performance Data
0607-003