3OM-1343-008_w.pdf - 第245页
6-14 AKFEDT -ID Feeder offset parameters are added to actual of fset values. Actual Offset V alues = Feeder (A) Offset + Feeder (B) Offset Note Perform the same operations for the feeders (Feeder Base #1: 101 to 150, #2:…

6-13
AKFEDT-ID
2.1.3 Feeder Offset A and Feeder Offset B
When the "Fdr-A" or the "Fdr-B" tab is pressed in the "Device Offset" tab
sheet, the corresponding tab sheet appears as shown below.
Note
Another tab sheet can be opened by pressing the corresponding "Feeder
Base" tab.
[1] [2]
Fig. 3F12
"
Fdr-A
"
Tab Sheet
Feeder Offset A
This offset data is used to correct variation in each feeder slot (Fdr No.) of
the feeder base.
•
The parameters measured at shipment of the machine are entered.
Do not change the parameters unless necessary.
Feeder Offset B
This offset data is used to correct variation in the feeder.
•
The X and Y parameters are recognition-processed during the automatic
operation to track the positional relation between the nozzle and component
centers and updated automatically for better pickup posture (pickup on the
component center).
Note:
In normal cases, it is not necessary to enter any parameters.
•
The "L [mm]" parameters are not updated automatically but the entered
ones are refl ected.
2.1 Device Offset Data
0607-003

6-14
AKFEDT-ID
Feeder offset parameters are added to actual offset values.
Actual Offset Values = Feeder (A) Offset + Feeder (B) Offset
Note
Perform the same operations for the feeders (Feeder Base #1: 101 to 150,
#2: 201 to 250, #3: 301 to 350, and #4: 401 to 450) on each feeder base at
the "Feeder Base #1" through "Feeder Base #4" tab sheets.
Offset Parameters
Set the following offset values for each individual feeders (Feeder Base
#1: 101 to 150, #2: 201 to 250, #3: 301 to 350, and #4: 401 to 450).
2.1 Device Offset Data
0601-002

6-15
AKFEDT-ID
[1] X (Horizontal) and Y (Vertical) [mm]
These offset parameters are used to adjust the positional deviation based
on the design dimensions representing the component pickup position
for each individual feeder slot Nos. (Fdr Nos.).
F211
F111
Rear Feeder
Front Feeder
Front Side of Machine
Y (+)
X (+)
Pickup Position
Pickup Position
Direction of Tape FeedDirection of Tape Feed
Fig. 3F13
[2] L (Height) [mm]
Nozzle
L (+)
Pickup Reference Level
Fig. 3F14
When a value is entered with a plus (+) sign, the pickup height is refl ected on
the direction in which the descending stroke of the nozzle will increase.
2.1 Device Offset Data
0601-002