3OM-1343-008_w.pdf - 第269页

6-38 AKFEDT -ID 2.1.17 Nozzle Up/Down Offset When the "Nozzle" tab is pressed in the "Device Offset" tab sheet and the "Nozzle Up/Down" tab is selected, the following tab sheet appears. Fig.…

100%1 / 343
6-37
AKFEDT-ID
Nozzles 1 through 12
Head #1, Head #2, Head #3, and Head #4
X (Horizontal), Y (Vertical) [mm]
The set parameters are used to adjust the deviations from the design
value between the head rotational center and each nozzle end position.
Xm (+)
Ym (+)
Xm-Ym : Machine Reference
Coordinate System
DD (+)
DD (+)
1
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
Actual Nozzle Position
Pm. Machine Reference
Coordinate Origin
2
Design Value of Nozzle Position
Fig. 3F35
2.1 Device Offset Data
0601-002
6-38
AKFEDT-ID
2.1.17 Nozzle Up/Down Offset
When the "Nozzle" tab is pressed in the "Device Offset" tab sheet and the
"Nozzle Up/Down" tab is selected, the following tab sheet appears.
Fig. 3F36 "Nozzle Up/Down" Tab Sheet
Nozzles 1 through 12
Head #1, Head #2, Head #3, and Head #4
L (Height) [mm]
The set parameters are the offsets based on the design value (gap)
between the upper surfaces of the nozzles and the nozzle U/D levers.
2.1 Device Offset Data
0607-003
6-39
AKFEDT-ID
2.1.18 Master Nozzle Level Offset
When the "Nozzle" tab is pressed in the "Device Offset" tab sheet and the
"Master Nozzle Level" tab is selected, the following tab sheet appears.
Fig. 3F37 "Master Nozzle Level" Tab Sheet
Head 1, Head 2, Head 3, and Head 4
L (Height) [mm]
Each parameter indicates the reference position (the values read by the
linear measure) of the master nozzle bottom level.
Save the values of the master nozzle bottom level that was read by the
linear measure and used when the head up/down offsets were obtained
with the nozzle U/D axes being zeroed.
2.1 Device Offset Data
0607-003