00197964-01_AI_Flex-Head-Options-Configuration_en - 第13页

Installing Flex Option 1 Assembly Instructions SIPLACE E 13 2 2 I n s t a llin g F le x O p t io n 1 Installing Flex Option 1 ▪ A sta ndard ma chine with NC FLEX std. cpl [ 03107775-xx] is equipped with one m agazine ho …

100%1 / 24
Introduction
Staff Qualifications and Training 1.3.6 SIPLACE on the World Wide Web (WWW)
12 Assembly Instructions SIPLACE E
1.4
1.4 Staff Qualifications and Training
Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op
-
eration and maintenance of automatic placement systems and add-on devices and are suitably qualified,
e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord
-
ance with normal safety standards.
Have received first aid training.
1.5
1.5 Abbreviations
Abbreviations
Abbreviations Description
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP14, CP12 and/or CP6
CP6 SIPLACE CP6, Collect&Place head with 6 segments
CP12 SIPLACE CP12, Collect&Place head with 12 segments
CP14 SIPLACE CP14, Collect&Place head with 14 segments
EMC Electromagnetic compatibility
ESD Electrostatic sensitive device
HMI Human machine interface (Operator panel)
JTF-MW JEDEC Tray Feeder (Automatic tray changer)
PCB Printed circuit board
P&P Pick&Place
PP SIPLACE PP, Pick&Place head
SC Station computer
TH SIPLACE TH, Twin Pick&Place head
Installing Flex Option 1
Assembly Instructions SIPLACE E 13
2
2 Installing Flex Option 1
Installing Flex Option 1
A standard machine with NC FLEX std. cpl [03107775-xx] is equipped with one magazine holder with
two passive nozzle magazines of type [03103613-xx] and one passive nozzle magazine of type
[03109863-xx] at location 2.1.
The large reject bin [03109719- xx] is located on the left at Location 2. The small reject bin
[03109739-xx] is located on the left at location 1.
Passive Nozzle Magazine Type (Quick Reference)
Standard Flex Flex Option 1
2x Magazine cpl. / 2 nozzles P&P / E-series
[03103613
-
xx]
1x Magazine cpl. / 1 nozzle P&P / E-series
[03109863
-
xx]
1 Location 1 2 Location 2
Flex Option 1 Configuration NC FLEX LOC 2.2 cpl. [03113126-xx] is located at the highlighted area.
It consists of a magazine holder with a flexible number of passive nozzle magazines ([03103613-xx] or
[03109863-xx]).
The order quantity depends on the customer's preference.
Installing Flex Option 1
14 Assembly Instructions SIPLACE E
Installation Procedures (Taking Location 2.1 as an Example)
Place the height measurement block FLEX LOC2 [03118537-xx] onto the shim cover and move head
holder manually towards the block with care.
Check the gap with a feeler gauge (1).
Determine the gap and the number of NC shims [03108395-xx] required.
Magazine holder single and double P+P magazine
Place the magazine holder cpl./NC P+P/E-series [03103612-xx] onto the shim cover once the height
is adjusted.
Secure it with four M5x20 cap screws at both ends.
Height measurement block FLEX LOC2 [03118537-xx] is required to up
-
grade in the field.
Mount the shim cover [03108393-xx] onto the mounting block Flex
[03106636-xx] at location 2.
Mount the required shims underneath the shim cover and fasten them
with an M3x8 countersunk screw.