Dek-265GSX-User-Manual - 第141页

Disk This column lists which events are logged to the disk file. The events set to ‘on’ are logged, those set to ‘off’ are not logged. Host This column lists which events are sent to the host computer. The option is only…

100%1 / 388
Comms Protocol Sets the communications protocol to be used for serial communications to a host
computer, options are:
Secs; GEM; Net_file; No Comms
The menu bar changes depending on the option chosen, see the Host
Communications Chapter for further details.
NOTE
Host Comms is available for the 265GSX only.
CAUTION
Do not select SECS Protocol without having the SECS II Interface fitted to
the Machine. If this is inadvertently selected, call DEK Service Dept. for
advice.
Event Recording Sets which events are recorded in the event log file, options are:
Custom; Group 3; Group 2; Group 1
The default is Custom.
Over 200 possible events may be recorded using the event logging set
preference.
On selecting Custom in the Event Recording set preference the following set up
window opens:
The window displays how each event is logged in the three possible ways; Disk,
Host and Grp.
2.6 User Manual Software Version 6
SET PREFERENCES
PREFERENCES
WARNING
SAFETYDEVICES. THE SAFETYFEATURES DESIGNED INTOTHE
MACHINE ARE FOR THE PROTECTION OF ALL OPERATOR AND
MAINTENANCE PERSONNEL. DEK STRONGLY RECOMMEND
SAFETYDEVICESARENEVEROVERRIDDEN.
Event Report Setting: Disk Host Grp
System Power On
System Power Down
Pneumatic Power Down
Front Squeegee Error
Rear Squeegee Error
Rising Table Error
Print Cariage Error
Paste Carriage Error
Camera X Axis Error
Camera YAxis Error
Rail Width Error
Screen XF Error
Screen XR Error
on
on
on
on
on
on
on
on
on
on
on
on
on
on
off
off
off
off
off
off
off
off
off
off
off
off
off
off
1
1
2
3
2
2
1
1
1
3
3
3
1
1
...more
Disk This column lists which events are logged to the disk file. The events set to ‘on’
are logged, those set to ‘off’ are not logged.
Host This column lists which events are sent to the host computer. The option is only
active if aGEM host comms interface is fitted. The events set to ‘on’ are logged,
those set to ‘off’ are not. How the host computer deals with the event logging,
depends on the host software and is not controlled by the 265 machine.
Grp This parameter allows the user to assign events to one of three groups. The user
can select from the Event Logging set preference which of the groups are to be
recorded, as follows:
Set Preference Selection Event Groups Recorded
Group 1 Groups 1, 2 and 3 (all events)
Group 2 Groups 2 and 3
Group 3 Group 3
Setting Up Events The Event Recording menu is laid out as follows:
Use the Next and Previous keys to move to the event to be changed.
Usethe Toggle key to toggle the Disk andHostparametersbetweenonand off.
Use the Left and Right keys to move to the Disk, Host or Grp columns.
Use the Incr. and Decr. keys to change the value of the Grp parameter.
Use Exit to leave the Event Recording window.
Recordable Events The following table shows the events that can be selected for recording:
System Power On System Power Down Humidity
Temperature Batch Count Measured Cycle Time
Throughput Cycle Time Front Print Pressure Rear Print Presure
Table Separation Speed Stretch Error X Error
Y Error Theta Error Board Fid 1 Score
Board Fid 2 Score Board Fid 3 Score Screen Fid 1 Score
Screen Fid 2 Score Screen Fid 3 Score ProFlow System Pressure
Pneumatic Power Down Front Squeegee Error Rear Squeegee Error
Rising Table Error Print Carriage Error Paste Carriage Error
Camera X Axis Error Camera Y Axis Error Rail Width Error
Screen XF error Screen XR Error Screen Y Error
Paste Cartridge Tilt Error Screen Changer Drive Error Board Stop Stuck
Software Version 6 User Manual 2.7
SET PREFERENCES
PREFERENCES
Board Clamp Stuck Board Stuck In Rails Unable To Find Fiducial
Rail Lifted Error Pressure Error File Error
Unable To Recover Recovery Started Recovered
Upline Transfer Error Downline Transfer Error Dual Shuttle Fault
Screen Elevator Comms Fault Screen Elevator Fault Screen Changer Fault
Lid Bolt Fault Alignment Out Of Range Line Power On
Line Power Off Cover Open Cover Closed
Printer Ready Head Raised Head Closed
Paste Dispensing Paste Cartridge Empty Cycle Aborted
Cycle Completed Cleaning Screen Parameter Adjusted
Setup Started Product Loaded New Product
Product Data Changed Screen Unloaded Screen Loaded
Tool Change Started Tool Change Complete Setup Ended
Start Print Cycle Board Received End Print Cycle
Printed Board Ready Board Printed Operator Log On
Operator Log Off Clear Batch Count Start Maintenance
End Maintenance Pressure Recalibrated Offset Recalibrated
XY Scale Recalibrated Theta Recalibrated Configuration Changed
Start Diagnostics End Diagnostics Flood Height Reset
Camera Ref Reset Thickness Recalibrated Vision Height Reset
Print Height Reset Autoflex Status Reset Software Updated
New Event Log Front Reference Position Reset Front Reference Height Reset
Rear Reference Height Reset Check Cleaner Paper Cleaner Solvent Low
Barcode Read Failure Barcode Mismatch Screen Couplings Not Extended
Mint Reply Timeout Camera X Failed To Position Camera Y Failed To Position
Aperture Blockage Stencil Smear Paste Present
Bridging alarm Alignment Alarm Head Left Partly Open
Head Moved To Safe State Inspection Cycle Complete Clock Change Request
Clock Changed Board Delivered and Removed Event Log Disc File Full
ProFlow Error Autoflex Tooling Selected Autoflex Tooling Deselected
AutoFlex Tooling Enabled AutoFlex Tooling Disabled Tooling Data Has Been Changed
CAN Node Comms Lost. Node CAN Node Comms Active. Node CAN Bus Comms Lost. Bus
CAN Bus Comms Active. Bus Invalid CAN Response Product Directory Request
Current Product Request Erase Product Request Rename Product Request
Load Product Request Download Product Request Upload Product Request
Download Configuration Request Upload Configuration Request Upload Management Data Request
Clear Batch Data Request Clear Session Data Request Upload Event Log Request
Clear Event Log Request Comms Start Request Comms Stop Request
Update Mode Request Comms Error Parameter Info Uploaded
Formatted Parameters Uploaded Formatted Parameters Downloaded Comms Status Request
Comms Rebuild Product List Comms Adjust Paste Rate Comms Adjust Front Pressure
Comms Adjust Rear Pressure Comms Adjust Print Gap Comms Adjust Seperation Speed
Comms Adjust Clean Screen Comms Adjust FWD_X Offset Comms Adjust FWD_Y Offset
Comms Adjust FWD_T Offset Comms Adjust REV_X Offset Comms Adjust REV_Y Offset
Comms Adjust REV_T Offset Comms Dispense Paste Request Comms Clean Screen Request
2.8 User Manual Software Version 6
SET PREFERENCES
PREFERENCES