Remote Barcode Hardware This preference is only available if the TCP/IP version of Host Comms is used and Serial Host Comms is not selected from the Comms Protocol set preference, options are: Enabled; Disabled The optio…

100%1 / 388
Comms Enabled Comms Disabled Equipment Constant Change
Acknowledge Terminal Message Comms Knead Paste Request Comms Condition Paste Request
Control State Change To Local Control State change To Offline Control State Change To Remote
GEM Spooling Activated Gem Spooling Deactivated GEM Spool Transmission Failure
Operator Command Issued Remote Barcode Received Comms Adjust ProFlow Pressure
Options.enb file Attribute Error Volume Alarm Evaluation Dongle Detected
Valid Dongle Detected Dongle Error Dongle Changed
Print Speed Front Print Speed Rear Print Speed
Comms Adjust Print Speed Comms Adjust Front Print Speed Comms Adjust Rear Print Speed
Vortex Cassette Replaced Maintenance Monitoring Initialis The Monthly Service is Due
The Six Monthly Service is Due The Yearly Service is Due Equipment Recovery
Equipment Setup Equipment Ready Equipment Maintenance
Equipment Waiting Equipment Running Equipment Down
Tooling Hardware Sets which type of tooling is fitted, options are:
Autoflex; Vacuum; Magnetic; Vac For Flex
The default is Magnetic.
Autoflex Entry Sets whether the Fine Pitch Autoflex pin co-ordinates are referenced by the
distance of the pin, in X and Y, from the front left of the Autoflex table
(absolute), or from the column letters and row numbers (grid), options are:
Absolute; Grid
Fiducial Reference Sets whether the fiducial co-ordinates are specified relative to the front/left or
front/right corner of the board:
Left; Right
The default is Left.
Product Barcode
H/W
Sets whether or not the product barcode reader is fitted (265GSX only), options
are:
Fitted; Not Fitted
Screen Barcode
H/W
Sets whether or not the screen barcode reader is fitted (265GSX only), options
are:
Fitted; Not Fitted
Software Version 6 User Manual 2.9
SET PREFERENCES
PREFERENCES
Remote Barcode
Hardware
This preference is only available if the TCP/IP version of Host Comms is used
and Serial Host Comms is not selected from the Comms Protocol set preference,
options are:
Enabled; Disabled
The optional External Product Barcode Reader provides a generic bar code
interface for the capturing by GEM and SPC of a product bar code before the
product is passed to the printer. Use of the reader enables a host program to
decide on the action to be taken for this product and provides a method for SPC
to log product details for tracking.
The DEK printer acts as a dumb receiver of barcode data and provides no set up,
configuration or triggering information for the barcode reader.
Compatible Bar
Code Reader
The printer has been designed to operate with SICK Model CLV 212 Bar code
reader.
Options The two options available for the External Barcode parameter are Enabled and
Disabled.
If the bar code reader is set to Disabled, COM 1 is setup as per previous versions
of software and enabled to accept serial host comms.
If the bar code readeris set to Enabled, COM 1 isset to use the external bar code
reader and the option Serial Comms is removed from the Comms Protocol
parameter in the Set Preferences menu.
ProFlow Contact
Position
This parameter sets the height of theProFlow printhead so that it just touches the
stencil surface.
Min - 10mm
Max + 10mm
Increments 0.1mm
The default is 0mm.
ProFlow Down Stop
Position
This parameter pre-tensions the squeegee suspension springs to provide
ProFlow with a zero pressure datum.
Min - 10mm
Max 10mm
Increments 0.1mm
The default is 0mm.
2.10 User Manual Software Version 6
SET PREFERENCES
PREFERENCES
Change Mode
Option
Sets the screen change mode, options are:
Manual; Dual Shuttle
NOTE
The dual shuttle option is only relevant on a machine with a dual shuttle unit
fitted.
Screen Size Sets the screen size frame:
265; FUJI; 249; SANYO; SCREEN LIBRARY
With Screen Library enabled the printer is provided with detailed screen
dimensional information from a ‘read only’ library. This information is stored
within the machine configuration and product files.
Once selected in Set Preferences, detailed frame dimensions are provided to the
printer. In Edit Current Process Parameters, the parameter Image Data provides
comprehensive location and mesh details to the printer.
To enable screen library files carry out the following:
1.
Highlight Screen Size in the Set Prefs page.
2.
Using Incr. or Decr. select Screen Library.
Edit Data is now available on the menu bar.
3.
Select Edit Data, the following window and menu bar is displayed:
Use Incr.orDecr. to select the required Screen Type. If no valid screen library
files are found, the default file DEK 265 Central Image is displayed.
Use Next or Previous to select and Incr. or Decr. to modify the screen frame
parameters as required.
Software Version 6 User Manual 2.11
SET PREFERENCES
PREFERENCES
SCREEN TYPE
SCREEN LENGTH
SCREEN WIDTH
FRAME FRONT
FRAME REAR
FRAME LEFT
FRAME RIGHT
DEK 265 CENTRAL IMAGE
XXX
XXX
XXX
XXX
XXX
XXX
mm
mm
mm
mm
mm
mm
Screen Frame Configuration