ERROR RECOVERY Abort Pressing this option re-initializes the entire printer, ejecting any product that may be in the printer and returning to the main control page. Retry Selecting this option re-checks the error conditi…

ERROR MESSAGES
INTRODUCTION If for anyreason the machinedoes not completea particular sequencein the time
allowed for in software, then an error condition arises. The relevant error
message is displayed on the main control screen.
Machine Errors are detected by sensors specifically designed for checking
correct machine status (System Power, Pneumatic Power, etc.) or by functions
failing to achieve their correct operation. These latter errors are either detected
by a limit sensor being operated or by setting a time limit for their completion.
The time limits are set so they are 1.5 times the longest possible time taken for
thatparticularoperation,after which, if not completed, an error is reported on the
main control screen.
When an error occurs the relevant message is displayed on the main control
screen. The displayed error message is accompanied by information regarding
the possible causes and the corrective action to be taken.
TheTricolour beacon changes to red and records the errorintheEventLog file.
Software Version 6 User Manual 4.1
ERROR MESSAGES
INTRODUCTION

ERROR RECOVERY
Abort Pressingthis option re-initializes the entire printer, ejecting any product that may
be in the printer and returning to the main control page.
Retry Selectingthis option re-checks the errorcondition and ifclear continuesthe print
cycle.
Recover Pressing this option attemptsto continue withany cycle thatis in operation. This
function sets modules (paste dispenser, print carriage, etc.) to their home
position and then ejects the board that is currently in the printer without
re-initializing the machine. This option should be the first to be operated if there
is an error reported.
Diagnostics This option is only displayed if diagnostics is selected by the keyswitch. It
enables the diagnostics to be entered immediately, normally by a technician, for
more in-depth investigation of the problem.
Head This allows the operator to operate the ‘Head’ function to gain access under the
printhead.
Continue When this option isavailable, selecting the continue keyclears the error message
and continue with the cycle that is in operation.
Fiducial setup When this option is available, selecting the Fiducial Setup key allows the user to
relearn the reported ‘Not Found’ fiducial.
Auto Search When this option is available, selecting the Auto Search key instigates a search
within the selected window size to locate the ‘Not Found’ fiducial.
Search Step When this option is available, selecting the Search Step key moves the camera
the first step in a search procedure designed to locate the ‘Not Found’ fiducial.
Further selection of the key moves the camera to the second step etc. Once the
fiducial is visible in the region of interest, the Retry key can be selected to
capture the fiducial.
Search Reset When this option is available, selecting the Search Reset key returns the camera
to its original position, before the Search Step key was selected. This is the
position from which the ‘Not Found’ fiducial was reported.
4.2 User Manual Software Version 6
ERROR MESSAGES
ERROR RECOVERY

ERROR MESSAGE LISTING
Error Message Intrepretation
Action Command Error This error reports that an undefined return status message from the
mint is received. A possible cause is :
Communication problems between the mint and the MOD801
card.
Alignment Out of Range This indicates that the actuator positions required to achieve a
satisfactory alignment are not achievable.
Alignment Close to Limit/Out of
Range
Actuator limit exceeded.
Autoflex Timed Out This error reports that with the autoflex tooling on high power and
the tooling pins up, the process time of 5 minutes has been
exceeded. When this message is displayed the power is also
switched to low.
Board Detected At Board Stop,
Print Terminated.
With the machine running in any mode, this error reports that the
board stop sensor has been activated out of sequence.
Possible causes are:
Board already loaded into the machine.
Sensor is detecting tooling.
Sensor is faulty.
Board Fiducial Not Found This error reports that the vision system has been unable to locate
the board fiducial.
Board Not Over Input Sensor This error reports a machine has stared without a board on the
rails. The user has ignored the message to place a board on the
rails and selects continue on the machine.
Board On Rails, Remove and
Continue
This error reports that a board has been sensed on the rails during
one of the following operations:
Initialization
Loading a new board file
Entering the rail system in diagnostics.
Board Stop Not Lowered This error reports that the board stop is up and has not lowered
within the time-out period of 3 seconds. The possible causes are:
Board stop sensor, enter diagnostics and check the sensor changes
state.
Air pressure failure to the board stop.
Board Stop Not Retracted This error reports that the board stop is down and has not retracted
within the time-out period of 3 seconds. A possible cause is:
Board stop sensor - enter diagnostics, digital inputs and check the
sensor changes state.
Board Stop Stuck This error reports that the board stop, which is housed in the
camera assembly has failed to lower or retract.
Board Stuck in Rails This error reports that the board has failed to either reach the board
stop or exit the machine after being printed.
Camera X Axis Error This error reports that the camera carriage has failed to reach its
home position in the X axis.
Camera Y Axis Error This error reports that the camera carriage has failed to reach its
home position in the Y axis.
Software Version 6 User Manual 4.3
ERROR MESSAGES
ERROR MESSAGE LISTING