SQUEEGEE The Squeegee diagnostic module contains the following: Home Front Squeegee Home Rear Squeegee Front Squeegee to Dwell Height Rear Squeegee to Dwell Height Rear Squeegee to Flood Height Drive Front Squeegee Using…

100%1 / 388
Drive System to
Contact Height
Selecting this option drives the ProFlow unit onto the screen, (a slight pressure
seal, is made between the ProFlow transfer head and the screen). There is no
pressure applied to the paste cassette.
Drive System to
Printing Height
Selecting this option drives the ProFlow transfer head down to printing pressure
(as setup in the Edit Data board file). There is no pressure applied to the paste
cassette at this time.
Home Downstop Selecting this option drives the downstop to home position (fully raised).
Drive Downstop
to Position
Selecting this option drives the downstop to the preset downstop position (offset
canalsobeadjustedinthestatusmenupage by selecting Maint. and selecting Set
Prefs menu).
Drive System
Using Jog Buttons
Moves the ProFlow unit up or down by means of the jog buttons.
Drive Downstop
Using Jog Buttons
Moves the downstop up or down by means of the jog buttons.
Toggle Paste
Pressure
Initiates pressure onto the paste system. Before initiating pressure to the paste
system, the transfer head must be in contact with,and have an adequate seal with
the screen. A warning is displayed if toggle paste pressure is selected with the
transfer head off the screen.
Pressure Reading Continuously displays the current pressure in kg exerted from the squeegee
pressure load cell onto the ProFlow unit.
ProFlow Fitted Indication of electrical connection of ProFlow to the machine software.
Paste Cassette Low ProFlow paste low sensor activated (on), indicating paste low or empty or,
deactivated (off).
ProFlow Pressure
Regulator Fitted
Switched to OFF indicates that the ProFlow unit is fitted with a mechanical
pressure regulator control. Switched to ON indicates that the software
addressable regulator control is activated, (ProFlow unit not fitted with
mechanical pressure regulator).
Software Version 6 User Manual 5.19
DIAGNOSTICS
PROFLOW
SQUEEGEE The Squeegee diagnostic module contains the following:
Home Front Squeegee
Home Rear Squeegee
Front Squeegee to Dwell Height
Rear Squeegee to Dwell Height
Rear Squeegee to Flood Height
Drive Front Squeegee Using Jog Buttons
Drive Rear Squeegee Using Jog Buttons
Pressure Reading. . . . .kg
The menu bar changes to the following:
RunDiagnost activates the diagnostic function, as selected by thehighlightbar.
Next/Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Exit returns operation to the module diagnostics page.
Home Front
Squeegee
Selecting this option drives the front squeegee upwards to its home position as
detected by its home sensor.
Home Rear
Squeegee
Selecting this option drives the rear squeegee upwards to its home position as
detected by its home sensor.
Front Squeegee to
Dwell Height
This option drives the front squeegee to a position 10mm clear of the top of the
screen.
Rear Squeegee to
Dwell Height
This option drives the rear squeegee to a position 10mm clear of the top of the
screen.
Rear Squeegee to
Flood Height
This option drives the rear squeegee to the height set by the flood reference
height parameter.
Drive Front
Squeegee Using
Jog Buttons
Selecting this option enables theright jogbutton todrive the front squeegee upat
slow speed and the left jog button drives it down, stopping immediately the
buttonisreleased. “Use the two button controls to drive the Squeegee to front” is
displayed in the prompt box.
5.20 User Manual Software Version 6
DIAGNOSTICS
SQUEEGEE
Drive Rear
Squeegee Using
Jog Buttons
Selecting this option enables the right jog button to drive the rear squeegee up at
slow speed and the left jog button drives it down, stopping immediately the
button is released. “Use the two button controls to drive the Squeegee to rear” is
displayed in the prompt box.
Pressure Reading This is a live display showing the actual pressure being applied to the squeegee.
With no squeegee fitted the display should show a reading of approximately
3.6kg.
Software Version 6 User Manual 5.21
DIAGNOSTICS
SQUEEGEE