CAMERA AXES The Camera Axes diagnostic module contains the following: The menu bar changes to the following: Run Diagnost activates the diagnostic function, as selected by the highlight bar. Next/Previous keys move the h…

Drive Rear
Squeegee Using
Jog Buttons
Selecting this option enables the right jog button to drive the rear squeegee up at
slow speed and the left jog button drives it down, stopping immediately the
button is released. “Use the two button controls to drive the Squeegee to rear” is
displayed in the prompt box.
Pressure Reading This is a live display showing the actual pressure being applied to the squeegee.
With no squeegee fitted the display should show a reading of approximately
3.6kg.
Software Version 6 User Manual 5.21
DIAGNOSTICS
SQUEEGEE

CAMERA AXES The Camera Axes diagnostic module contains the following:
The menu bar changes to the following:
RunDiagnost activates the diagnostic function, as selected by thehighlightbar.
Next/Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Exit returns operation to the module diagnostics page.
Fiducial Setup enables screen fiducials to be located.
Adjust opens the following window:
The menu bar changes to the following:
Incr.
Next/Previous keys move the highlight bar up and down the list of diagnostic
parameters.
Incr./Decr. keys change the value of the selected diagnostic parameter.
Exit returns operation to the camera axes diagnostics page.
5.22 User Manual Software Version 6
DIAGNOSTICS
CAMERA AXES
Camera D
i
agnost
i
cs
Home Camera X Axis
Home Camera YAxis
Camera Axis To Fiducial 1 Position
Camera Axis To Fiducial 2 Position
Camera Axis To Fiducial 3 Position
Drive to Board Stop Position
Restore Default Reference Position
Drive to Reference Position
Set Reference Position
Move Camera X Axis Using Jog Buttons
Move Camera YAxis Using Jog Buttons
Initialise Vision System
Fiducial Lighting
Inspection Lighting
ON
ON
.. more
FIDUCIAL 1 X
FIDUCIAL 1 Y
FIDUCIAL 2 X
FIDUCIAL 2 Y
FIDUCIAL 3 X
FIDUCIAL 3 Y
BOARD STOP X
BOARD STOP Y
CYCLE COUNT
Camera Cycle Test Parameters
243.0
241.1
7.3
8.8
0.0
0.0
125.0
165.0
50.0
mm
mm
mm
mm
mm
mm
mm
mm
Cycles

NOTE
These parameters are used in diagnostics only and have no affect on the product
board file.
Home Camera
X Axis
Selecting this option drives the Camera X carriage to find its datum position as
determined by it’s home sensor.
Home Camera
Y Axis
Selecting this option drives the Camera Y carriage to find its datum position as
determined by it’s home sensor.
Camera Axis to
Fiducial 1 Position
Selecting this option drives both X and Y carriages to the position set by the
fiducial 1 X and Y coord parameters.
Camera Axis to
Fiducial 2 Position
Selecting this option drives both X and Y carriages to the position set by the
fiducial 2 X and Y coord parameters.
Camera Axis to
Fiducial 3 Position
Selecting this option drives both X and Y carriages to the position set by the
fiducial 3 X and Y coord parameters.
Drive to Board Stop
Position
Selecting this option drives both X and Y carriages to the position of the board
stop for the current product.
Restore Default
Reference Position
Selecting this option restores the reference position stored as a default in
software.
Drive to Reference
Position
Selecting this option enables drive to both X and Y carriages, to the position set
by the camera X and Y reference parameters.
Set Reference
Position
Selecting this option alters the Printer Configuration file after the camera has
been positioned so that it is viewing the reference mark on the front rail. On
selection of this option the Menu Bar displays Confirm, pressing this key alters
the printer configuration file. This is used in conjunction with Move camera X
and Y axes.
Move Camera X
Axis Using Jog
Buttons
Selectingthisoptionenables the right jog button to drive the camera in the Xaxis
to the left at slow speed and the left jog button drives the camera right, stopping
immediately the button is released, (see Note).
NOTE
This is a physical movement of the camera, not as displayed on the monitor.
Software Version 6 User Manual 5.23
DIAGNOSTICS
CAMERA AXES