SCREEN ALIGNMENT The Screen Alignment module contains the following: Home Actuator Drive X Forward Motor Using Jog Buttons Drive X Rear Motor Using Jog Buttons Drive Y Motor Using Jog Buttons Toggle Chase Clamp on/off Cy…

100%1 / 388
Cartridge in Down
Position
Continuously displays the current status of the cartridge away (down) sensor.
Cartridge in Up
Position
Continuously displays the current status of the cartridge home (up) sensor.
Software Version 6 User Manual 5.29
DIAGNOSTICS
PASTE DISPENSE SYSTEM
SCREEN ALIGNMENT
The Screen Alignment module contains the following:
Home Actuator
Drive X Forward Motor Using Jog Buttons
Drive X Rear Motor Using Jog Buttons
Drive Y Motor Using Jog Buttons
Toggle Chase Clamp on/off
Cycle Alignment System
Cycle Count Done: 0 To go: 50
The menu bar changes to the following:
RunDiagnost activates the diagnostic function, as selected by thehighlightbar.
Next/Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The menu bar changes to the following:
Incr.
Next/Previous keys have no function in this application.
Incr./Decr. keys change the value of the cycle count.
Exit returns operation to the screen alignment diagnostics page.
Home Actuator Selecting this option drives the X forward, X Rear and Y Axis actuators
simultaneously to find their datum positions as determined by their datum
sensors.
Drive X Forward
Motor Using
Jog Buttons
Selecting this option enables the right Jog button to drive the X forward actuator
right at slow speed and the left Jog button to drive it left, stopping immediately
the button is released.
5.30 User Manual Software Version 6
DIAGNOSTICS
SCREEN ALIGNMENT
Actuator Cycle Test Parameters
CYCLE COUNT
50.0
Cycles
Drive X Rear Motor
Using Jog Buttons
Selecting this option enables the right Jog button to drive the X rear actuator
right at slow speed and the left Jog button to drive it left, stopping immediately
the button is released.
Drive Y Motor
Using Jog Buttons
Selecting this option enables the right Jog button to drive the Y actuator right at
slow speed and the left Jog button to drive it left, stopping immediately the
button is released.
Toggle Chase
Clamp
Selecting this option alternately energises the Chase Clamp solenoid, displaying
On status and de-energise it, displaying Off status.
Cycle Alignment
System
Selecting this option starts a continuous cycle of driving the screen actuators to
each of the following positions in sequence, dwelling for 2 seconds at each point
and repeating the cycle.
Thepositions are given as XF, XR and Y inmmfromdatum and are as follows:
1 0, 0, 0.
2 +20, +10, +10.
3 0, 0, 0.
4 -20, -10, -10.
5 0, 0, 0.
6 +10, +20, -10.
7 0, 0, 0.
8 -10, -20, +10.
If data logging is enabled, every time the screen returns to 0,0,0, locate a screen
fiducial and its co-ordinatesappended to c:\PRINTER\SCREEN.DAT file. This
continuous cycling is terminated by selecting the stop key or when the set cycle
count has been reached (50).
Cycle Count This option displays the count when the module is being cycled.
Software Version 6 User Manual 5.31
DIAGNOSTICS
SCREEN ALIGNMENT