Dek-265GSX-User-Manual - 第277页

Adjustment During Print Cycle Most inspection parameters may be adjusted whilst a print cycle is in progress. The parameters that may be adjusted are: • Global Limits • Limit Sets • Site Parameters NOTE The site coordina…

100%1 / 388
8.12 User Manual Software Version 6
2Di INSPECTION
MODULE OVERVIEW
Adjust Lighting:
Adjust so all board pads are
white with sharp edges and
the screen is seen clearly.
Add Limits Sets:
Set wide tolerances so no
alarms occur.
Add Site:
Name, Location Etc
Ensure all pads are within
the search box.
Set Globals as required:
2D Inspect Rate = 0
Learn Site / Learn Board:
Adjust board graphic ‘X’
and ‘Y’ accurately
Exit out
Auto Scale:
Determine the print closest
to 100% and auto scale on
that pad
Inspect Site:
Paste present data for all
pads are close to the same
value ?
If Board Inspect Type set to
Advance, all the paste
toggles white or yellow on
the board ?
More Sites to Teach ?
Add the rest of the sites
using the same light
settings as this first one
Print Board:
Step through the cycle until
a board is printed.
Is it a good print ?
Exit out
Place a clean
board into the
machine.
Clean screen
Re-adjust Lighting:
Adjust the LED’s to balance
the lighting
Run Product:
Have QC Calc ?
Reset the Globals:
Set the min sites/cycle.
Set 2D Inspect Rate.
Re-adjust the Limit Sets:
The customer may have to
adjust these settings a few
times until the proper
values are found.
SPC Data:
Collect SPC
data on the
2Di. From
this data
derive the
proper ‘limit
sets’ settings.
Trial & Error:
Increase the
‘limit sets’ and
use the data
when it alarms
to derive the
proper
settings.
DONE
New Pre-image taken
Figure 8-13 2Di Inspection Setup Guide
Adjustment During
Print Cycle
Most inspection parameters may be adjusted whilst a print cycle is in progress.
The parameters that may be adjusted are:
Global Limits
Limit Sets
Site Parameters
NOTE
The site coordinate parameters are not available whilst a print cycle is in
progress.
To access the parameter adjustment menu during a print cycle select Adjust
Inspect.
Adjust
Inspect
The following window is displayed:
The New Pre-images button is only available if Pre-image is set to 1.
NOTE
If an error occurs when adjusting inspection parameters during a print cycle,
the adjustment page closes.
Any changes made are saved.
Software Version 6 User Manual 8.13
2Di INSPECTION
MODULE OVERVIEW
SiteName
SitePriority
StencilInspectType
BoardInspectType
SiteAlignment
LimitSetID
PasteScaling
SiteXCoord
SiteYCoord
SiteWidth
SiteHeight
IC27-1
General
Advanced
Advanced
XandY
Fine
1.00
39.4mm
71.2mm
3.00mm
4.00mm
2DInspectRate
StencilInspectType
BoardInspectType
Pre-image
Min.Sites/Cycle
WarningLimit
BlockageAction
BlockageClean
SmearAction
SmearClean
LowPasteAction
InspectAfterClean
PostPrintAlignment
No.Sites
1
Advanced
Advanced
Every
10
3
Auto
Mode2
Manual
Mode1
Re-print
Enabled
Performed
30
GlobalInspectParameters
SiteParameters
2Di SETUP
Preparation For 2Di inspection functionality the machine requires 2D Inspection to be set to
enabled.
Set Preferences 1.
Select Maint.
Maint.
2.
Select Set Prefs.
Set
Prefs
3.
Set 2D inspection to enabled using the Next and Incr. keys.
Next Incr.
4.
Ensure under screen cleaner function selected, ie Vacuum or Standard.
5.
Select Exit. The message ‘Printer configuration data file saved’ is
displayed in the message prompt bar above the menu bar.
Exit
6.
Select Exit.
Exit
Load Product File 1.
Select Setup.
Setup
2.
Select Load Data. The message ‘Use keyboard to actionproduct search’
is displayed in the message prompt bar above the menu bar.
Load
Data
8.14 User Manual Software Version 6
2Di INSPECTION
2Di SETUP