21. Close the front printhead cover. 22. Press the System button. 23. Press Continue (F1). Continue 24. Press Exit (F8). Exit 25. Press Exit (F8). Exit Software Version 6 User Manual 9.63 CONSUMABLE REPLENISHMENTS PROFLO…

11. Remove both end retainers (skis).
12. Prior to fitting replacement items ensure the area around the wipers and skis
is free from print medium deposits.
13. Fit replacement wipers into position ensuring both wipers are fully home
against the wiper securing screws.
NOTE
If fitting stepped etched wipers, ensure that the stepped edge of each wiper is
facing outwards (wiper example in figure below refers).
14. Fully tighten the wiper retaining strip screws.
15. Loosen both end retainer brackets (if fitted).
NOTE
Retainer brackets are not fitted to the rechargeable transfer head.
16. Slide each ski between the wipers until they are flush with the ends of the
wipers, (ensure the air escape hole on each ski faces outwards of the unit, see
figure below).
17. Position both end retainer brackets and tighten the securing screws (if
applicable).
18. Fit the paste cover.
19. Slide the ProFlow transfer head unit onto the pressure mechanism mounting
rods and secure in place by hooking the ‘J’ action rotary latch onto the
transfer head chassis dowel pin and turn the latch clockwise.
20. Lower the pressure mechanism using the flush pull latch ensuring the
mechanism latch is engaged and is secured into place.
9.62 User Manual Software Version 6
CONSUMABLE REPLENISHMENTS
PROFLOW
Wiper Securing Screw
End Retainer (Ski)
Ski Air Escape Hole
Wiper
ProFlow Transfer Head (Inverted)
Wiper
Retaining Strip
Retainer Bracket
(if fitted)
Inverted Transfer Head (End View)

21. Close the front printhead cover.
22.
Press the System button.
23.
Press Continue (F1).
Continue
24.
Press Exit (F8).
Exit
25.
Press Exit (F8).
Exit
Software Version 6 User Manual 9.63
CONSUMABLE REPLENISHMENTS
PROFLOW

Rechargeable
Transfer Head
It is necessary at intervals to replenish the rechargeable transfer head. If there is
no print medium in the transfer head at the end of a print stroke, the warning
window ‘Print Medium Low. Please Replenish.’ is displayed.
Initial Filling If an empty/new rechargeable transfer head is to be used prior to printing. The
transfer head unit is to be initially charged in accordance with the following:
1. Fit the clean/new transfer head to the maintenance stand, so that the unit is
upside down.
2. Remove wipers, end retainers (skis) and the secondary ProFlow grid to gain
access to the primary grid.
3. Ensure that the long nosed nozzle is fitted to the recharging gun (mastic or
pneumatic gun).
4. Starting at one end of the centre row of holes in the primary grid, insert the
gun nozzle through the grid into the area adjacent to the diaphragm.
9.64 User Manual Software Version 6
CONSUMABLE REPLENISHMENTS
PROFLOW
WARNING
PROTECTIVE CLOTHING. APPROVED PROTECTIVE CLOTHIN
G
SHOULD BE WORN BY SOLDER PASTEAND SOLVENT HANDLERS
AT ALL TIMES TO ELIMINATE FUME INHALATION, EYE
CONTACT,SKINCONTACTANDINGESTION.
WARNING
SOLDERPASTEANDSOLVENTS. WHENUSINGORHANDLINGAN
Y
SOLDER PASTE OR SOLVENT FORMULATION THE
MANUFACTURERS' RECOMMENDED SAFETY PRECAUTIONS
MUSTBESTRICTLYADHEREDTO.
Long Recharging Nozzle