Dek-265GSX-User-Manual - 第379页
5. Fill the cavity until the paste starts to flow back up through the primary grid, extracting the nozzle slowly whilst continuing to fill. (This action fills the hole left by the nozzle.) 6. Move to the next available c…

Rechargeable
Transfer Head
It is necessary at intervals to replenish the rechargeable transfer head. If there is
no print medium in the transfer head at the end of a print stroke, the warning
window ‘Print Medium Low. Please Replenish.’ is displayed.
Initial Filling If an empty/new rechargeable transfer head is to be used prior to printing. The
transfer head unit is to be initially charged in accordance with the following:
1. Fit the clean/new transfer head to the maintenance stand, so that the unit is
upside down.
2. Remove wipers, end retainers (skis) and the secondary ProFlow grid to gain
access to the primary grid.
3. Ensure that the long nosed nozzle is fitted to the recharging gun (mastic or
pneumatic gun).
4. Starting at one end of the centre row of holes in the primary grid, insert the
gun nozzle through the grid into the area adjacent to the diaphragm.
9.64 User Manual Software Version 6
CONSUMABLE REPLENISHMENTS
PROFLOW
WARNING
PROTECTIVE CLOTHING. APPROVED PROTECTIVE CLOTHIN
G
SHOULD BE WORN BY SOLDER PASTEAND SOLVENT HANDLERS
AT ALL TIMES TO ELIMINATE FUME INHALATION, EYE
CONTACT,SKINCONTACTANDINGESTION.
WARNING
SOLDERPASTEANDSOLVENTS. WHENUSINGORHANDLINGAN
Y
SOLDER PASTE OR SOLVENT FORMULATION THE
MANUFACTURERS' RECOMMENDED SAFETY PRECAUTIONS
MUSTBESTRICTLYADHEREDTO.
Long Recharging Nozzle

5. Fill the cavity until the paste starts to flow back up through the primary grid,
extracting the nozzle slowly whilst continuing to fill. (This action fills the
hole left by the nozzle.)
6. Move to the next available centre hole, in the primary grid, that has not been
filled with paste. Repeat Steps 4 and 5.
7. Continue the above procedures until all the space below the primary grid is
topped up with paste.
NOTE
Ensure that there is little or no air bubbles trapped within the paste fill.
8. Re-fitthesecondaryProFlowgrid, wipers and end retainers (skis) to the unit.
9. Starting at one end of the centre row of holes in the secondary ProFlow grid,
insert the gun nozzle through the grid into the conditioning chamber area.
10. Fill the cavity until the paste starts to flow back up through the ProFlow grid,
extracting the nozzle slowly whilst continuing to fill. (This action fills the
hole left by the nozzle.)
11. Move to the next available centre hole, in the secondary grid, that has not
been filled with paste. Repeat Steps 9 and 10.
Software Version 6 User Manual 9.65
CONSUMABLE REPLENISHMENTS
PROFLOW
Long Recharging Nozzle

12. Fill the remaining space between the secondary grid and the working edges
ofthe wiper blades ensuring that the paste is level, (procedurebelowrefers).
13. Fit paste cover to the unit.
14. Remove the transfer head from the maintenance stand and fit the unit to the
ProFlow on the machine. (Refer to Technical Reference Manual, ProFlow
Chapter, Setting Up Procedures for detailed information on unit
removal/fitting.)
The transfer head can be replenished prior to and during a print run.
Prior to a Print Run The transfer head can be replenished prior to selecting Run.
1. If the ProFlow unit is in the home position continue with Step 2. If the
ProFlow unit is in the contact position go to Step 20.
2.
Select Setup (F6).
Setup
3.
Select Setup ProFlow (F4).
Setup
ProFlow
4.
Select Load Cassette (F4).
Load
Cassette
The message ‘Has the ProFlow unit’s base cover been removed?’ is
displayed.
5. If the ProFlow unit’s base cover is still fitted continue with Step 6. If the
ProFlow unit’s base cover has been removed go to Step 12.
9.66 User Manual Software Version 6
CONSUMABLE REPLENISHMENTS
PROFLOW