6. Select Remove Cover (F8). Remove Cover The message ‘Open the printer cover and remove the ProFlow unit’s base cover’ is displayed. 7. Open the printhead cover. 8. Remove the ProFlow unit’s base cover. 9. Close the fro…

12. Fill the remaining space between the secondary grid and the working edges
ofthe wiper blades ensuring that the paste is level, (procedurebelowrefers).
13. Fit paste cover to the unit.
14. Remove the transfer head from the maintenance stand and fit the unit to the
ProFlow on the machine. (Refer to Technical Reference Manual, ProFlow
Chapter, Setting Up Procedures for detailed information on unit
removal/fitting.)
The transfer head can be replenished prior to and during a print run.
Prior to a Print Run The transfer head can be replenished prior to selecting Run.
1. If the ProFlow unit is in the home position continue with Step 2. If the
ProFlow unit is in the contact position go to Step 20.
2.
Select Setup (F6).
Setup
3.
Select Setup ProFlow (F4).
Setup
ProFlow
4.
Select Load Cassette (F4).
Load
Cassette
The message ‘Has the ProFlow unit’s base cover been removed?’ is
displayed.
5. If the ProFlow unit’s base cover is still fitted continue with Step 6. If the
ProFlow unit’s base cover has been removed go to Step 12.
9.66 User Manual Software Version 6
CONSUMABLE REPLENISHMENTS
PROFLOW

6.
Select Remove Cover (F8).
Remove
Cover
The message ‘Open the printer cover and remove the ProFlow unit’s
base cover’ is displayed.
7. Open the printhead cover.
8. Remove the ProFlow unit’s base cover.
9. Close the front printhead cover.
10.
Press the System button.
Software Version 6 User Manual 9.67
CONSUMABLE REPLENISHMENTS
PROFLOW

11.
Select Exit (F8).
Exit
12.
Select Yes (F1).
Yes
The message ‘The ProFlow unit will be placed in the REAR envelope’ is
displayed.
13. Ifthe ProFlow unit is required to be placed in another envelope continue with
Step 14. If the ProFlow unit is required tobe placed inthe machine preferred
envelope go to Step 18.
NOTE
The ProFlow unit needs to be in the rear envelope to replenish the ProFlow
transfer head.
14.
Select Select Another (F8).
Select
Another
The following window is displayed:
15.
Use the Next or Previous keys (F4 or F5) to highlight Front.
Next Previous
16.
Select Use (F1).
Use
9.68 User Manual Software Version 6
CONSUMABLE REPLENISHMENTS
PROFLOW
Preferred Envelope
REAR
FRONT