Part 4 Chapter 3 Air Supply Edition 1.1 4-3-2 CP-6-series Mechanical Reference Notes:

100%1 / 331
Part 4 Chapter 3 Air Supply
Edition 1.1 4-3-1 CP-6-series Mechanical Reference
3. Air Supply
Point
Connect an external air supply hose to the machine and adjust the filter regulator to set
air pressure to the specified value.
Procedure
1. Attach a socket to the end of the air supply hose and connect the socket to the air
connector plug on the rear right-hand side of the machine.
2. Pull up the knob on the filter regulator to unlock it.
3. Turn the air inlet handle until the filter regulator reads 0.5 MPa (5 kgf/cm
2
).
4. Pull down the knob to lock it.
Note: Fuji does not supply the hose.
Plug (20 PM)
Hose (inner diameter: 8 mm)
Socket (20 SH)
Coupler
Standard
IEC compatible
CP6M4019
0.5 MPa (5 kgf/cm
2
)
Air inlet
Air inlet
(CP-652C only)
CP6M4018
Part 4 Chapter 3 Air Supply
Edition 1.1 4-3-2 CP-6-series Mechanical Reference
Notes:
Part 4 Chapter 4 Checking the Transformer Connections
Edition 1.0 4-4-1 CP-6-series Mechanical Reference
4. Checking the Transformer Connections
Point
Set the transformer inside of the CP-6 corresponding to the supply voltage. If the
transformer is set an incorrect input voltage, electrical parts may be damaged.
Procedure
<CP-6, CP-6M, CP-642, CP-642M, CP-643E, CP-643ME, CP-65>
Remove the screws on the cover and take the cover off. Check that the main transformer
is set to the specified input voltage.
<CP-652C>
Open the box cover, and check that the main transformer is set to the specified input
voltage.
R 1
S 1
U200V
U210V
U220V
U230V
U380V
U400V
U415V
U460V
U480V
V200V
V210V
V220V
V230V
V380V
V400V
V415V
V460V
V480V
W200V
W210V
W220V
W230V
W380V
W400V
W415V
W460V
W480V
T 1
R1 Red
S1 White
T1 Black
CP-652C
CP6M4020
CP-6, CP-6M, CP-642, CP-642M, CP-643E, CP-643ME, CP-65