5. Adjust the sensor ’ s mounting position by loosening the sensor lock screws and sliding the sensor in the front/back directions. CP6M5049 Sensor Lock screws Dog Part 5 Chapter 3 Station Adjustments Edition 1.0 5-3-30 …

3. Place a dial gauge on the nozzle UP/DOWN rod and set the gauge reading to “0”.
In this condition, the cam axis will be at its 0-degree position, and the nozzle
UP/DOWN rod will be at its UP limit position. Verify that the nozzle UP limit
sensor is ON (I/O INPORT X06B ST11 UP POS is ON).
4. While observing the dial gauge, rotate the cam axis in the forward direction to
lower the nozzle UP/DOWN rod. Adjust the sensor’s mounting position so that
the sensor switches OFF (I/O INPORT X06B ST11 UP POS switches OFF) when
the rod has been lowered 0.3 to 0.4 mm.
CP6M5048
Nozzle UP limit sensor OFF
Dog
Rod lowered
0.3 to 0.4 mm
CP6M5047
Nozzle UP limit sensor ON
Dog
Nozzle UP/DOWN rod
Set dial gauge to “0”
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-29 CP-6-series Mechanical Reference

5. Adjust the sensor’s mounting position by loosening the sensor lock screws and
sliding the sensor in the front/back directions.
CP6M5049
Sensor
Lock screws
Dog
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-30 CP-6-series Mechanical Reference

Nozzle DOWN Limit Sensor
Note: When performing the DOWN limit sensor adjustment after the UP limit sensor adjustment,
remove the dial gauge from the machine to avoid interference between the dial gauge and
the cam lever.
1. Set the cam axis to the 180-degree position.
2. Execute the following I/O commands to pull in the ST 11 placing stop cylinder
(located in the cam box):
[SET] - [MANUAL] - [I/O] - [Standard I/O] - [OUTPUT] -> Y028 PLACE SOL ON
The cam lever will then follow the cam axis.
3. Place a dial gauge on the nozzle UP/DOWN rod and set the gauge reading to “0”.
In this condition, the cam axis will be at its 180-degree position, and the nozzle
UP/DOWN rod will be at its DOWN limit position. Verify that the nozzle DOWN
limit sensor is ON (I/O INPORT X03F ST11 DN POS is ON).
CP6M5051
Nozzle DOWN limit sensor ON
Dog
Nozzle UP/DOWN rod
Set dial gauge to “0”
Solenoid valve
ST11 placing stop cylinder
Cam lever
Cam axis
CP6M5050
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-31 CP-6-series Mechanical Reference