Notes: Part 7 Chapter 2 Placement Accuracy Measurement Edition 1.0 7-2-14 CP-6-series Mechanical Reference

2.8.2 Procedure at PC
Setting the Communication Conditions
1. At the PC side, connect the transmission cable (machine <—> NTCC) to the port
which is not being used by NTCC. If there are no vacant ports, leave the cable as it
is, and end NTCC. (When NTCC is ended, acquisition of production information
from other machines is disabled.)
2. When using Windows NT 3.51
i) Start up the communication software at the PC as follows: “Program
Manager” —> “Accessories” —> “Terminal”.
ii) At the Terminal menu, select “Settings” —> “Communication Conditions”,
then specify the following settings:
Communication speed (bps): 9600
Flow control: Xon/off
Serial port: COM?
(PC port connected to transmission cable)
Data length: 8
Stop bit: 1
Parity: None
iii) At the menu, select [File] —> [Save As] to save the setting conditions. Once
saved, these settings are convenient when using the trace port (e.g.
trace.trm).
3. When using Windows NT 4.0
i) Click the START button, select “Accessories”, then start up the Hyper
Terminal.
ii) Enter the name (e.g., trace) at the connection settings, select the icon, then
click OK.
iii) Select the PC port (COM?) where the transmission cable is connected, then
click OK.
iv) At the port settings, specify the same settings as those at 2-ii) above, then
click OK.
v) At the menu, select [File] —> [Save] to save the setting conditions. A
shortcut is created at the START button (e.g. trace.ht).
Part 7 Chapter 2 Placement Accuracy Measurement
Edition 1.0 7-2-13 CP-6-series Mechanical Reference

Notes:
Part 7 Chapter 2 Placement Accuracy Measurement
Edition 1.0 7-2-14 CP-6-series Mechanical Reference