CP-6-series Mechanical Reference - 第316页
Leveling (Left-Right) Left-right tilt is controlled by the main vibration reduction unit. Although the machine’s left-right height is normally adjusted using adhesive pads, special adjusting plates are required when the …

1.3 Installation Procedure
The installation positions for the vibration reducing units are shown below.
1. Place adhesive pads at the top and bottom faces of each unit.
2. Install each unit at its prescribed position.
Note: Never inflate the pneumatic spring prior to installation under the machine. Inflating
the unit prior to installation can cause it to burst.
Adhesive Pads
The adhesive pads are used to prevent positional shifts between the vibration reduction
units, the floor and the machine. Although standard adhesive pads are 4 mm thick, pads
with a 2 mm thickness are also available for height adjustment purposes. When
necessary, use a combination of both styles of pads.
Adhesive Pad List
Location Size (units: m/m) Qty Remarks
Main vibration reduction unit
(bottom)
200 x 450 x t4 4
(200x 450 x t2) 4 Sizes shown in parentheses are
Main vibration reduction unit (top) 130x 450 x t4 4 height adjusting pads
(130 x 450 x t2) 4
Spring unit (W2Q-434S) GERB x t4 3
(top & bottom) (GERB x t2) 3
Pneumatic spring (top & bottom) 380x 380 x t4 2
(380 x 380 x t2) 1
417.5750745
2930
3180 355215
125
(125) (125)
125
3750
770790277.5
1055
CP6M11003
Machine top
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-3 CP-6-series Mechanical Reference

Leveling (Left-Right)
Left-right tilt is controlled by the main vibration reduction unit.
Although the machine’s left-right height is normally adjusted using adhesive pads,
special adjusting plates are required when the adjustment amount exceeds 5 mm.
These adjusting plates are available in 5, 10, 15 and 20 mm thicknesses.
Leveling (Front-Back)
Front-back tilt is automatically adjusted by the pneumatic spring. A leveling valve is
activated to maintain the setting height when the back of the machine drops below the
preset height.
Adjusting Plate List
Dwg. No. Part Name Qty Thickness
9851DWAB1000 Plate 2 5 mmthick
9851DWAB1010 Plate 2 10mmthick
9851DWAB1020 Plate 2 15mmthick
9851DWAB1030 Plate 2 20mmthick
CP-642
Adhesive pad
Adhesive pad
Adhesive pad
Vibration proofing unit
Adjusting plate
CP6M11004
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-4 CP-6-series Mechanical Reference

1.4 Air Valve Modification and Adjustment
Modification
Add the necessary components as shown in the illustration below.
List of Added Parts
Adjustment
Main Vibration Reduction Unit
When a large number of tape feeders are installed on the device table, the regulator [3]
should be set to its full-open position. If only a few tape feeders are installed on the
device table and the load is light, adjust the regulator as appropriate for this load.
Normally, a setting of 3 kgf/cm2 is appropriate, although the adjustment range is 1~5
kgf/cm2. A higher pressure setting causes more vibration to be transmitted to the floor,
resulting in less vibration at the machine. A lower pressure setting causes less vibration
to be transmitted to the floor, resulting in more vibration at the machine.
No Dwg. No. Part Name Qty Model
1 9851DWAB Union 1 TS6-02
2 9851DWAB Union 1 TS4-02
3 9851DWAB Regulator 1 R150-02
4 H1214A Straight pipe 3 1/4x25
5 T4038A T-union 2 1/4
6 T2064A Hose (ø8) 1 m TU0805B-20
5
4
3
1
6
5
2
44
CP6M11005
After Modification
To Main vibration reduction unit
To Pneumatic spring
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-5 CP-6-series Mechanical Reference