CP-6-series Mechanical Reference - 第318页

Pneumatic Spring Place a level on the machine, and adjust the Y-direction levelness only. The air supply timing is adjusted according to the length of the mechanical valve's bolt. Caution: Be sure that the rear side…

100%1 / 331
1.4 Air Valve Modification and Adjustment
Modification
Add the necessary components as shown in the illustration below.
List of Added Parts
Adjustment
Main Vibration Reduction Unit
When a large number of tape feeders are installed on the device table, the regulator [3]
should be set to its full-open position. If only a few tape feeders are installed on the
device table and the load is light, adjust the regulator as appropriate for this load.
Normally, a setting of 3 kgf/cm2 is appropriate, although the adjustment range is 1~5
kgf/cm2. A higher pressure setting causes more vibration to be transmitted to the floor,
resulting in less vibration at the machine. A lower pressure setting causes less vibration
to be transmitted to the floor, resulting in more vibration at the machine.
No Dwg. No. Part Name Qty Model
1 9851DWAB Union 1 TS6-02
2 9851DWAB Union 1 TS4-02
3 9851DWAB Regulator 1 R150-02
4 H1214A Straight pipe 3 1/4x25
5 T4038A T-union 2 1/4
6 T2064A Hose (ø8) 1 m TU0805B-20
5
4
3
1
6
5
2
44
CP6M11005
After Modification
To Main vibration reduction unit
To Pneumatic spring
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-5 CP-6-series Mechanical Reference
Pneumatic Spring
Place a level on the machine, and adjust the Y-direction levelness only. The air supply
timing is adjusted according to the length of the mechanical valve's bolt.
Caution: Be sure that the rear side of the machine is not too high.
1.5 Changing The Conveyor Link Bracket
Change to the brackets shown below.
List of Changed Parts
Dwg. No. Part Name Qty Type
93305WAB1000 BKT 2 Equivalent to previous Ctype
93305WAB1010 BKT 1 Equivalent to previous Gtype
CP6M1106
93305WAB1000
93305WAB1010
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-6 CP-6-series Mechanical Reference
Link Bracket Table
Next Stage Required BKT Remarks
LGC-4020B C, P, I
LGC-4020B C, I Reverse-flow
Previous Stage Required BKT Remarks
CAC-3100 GG, G
CAC-5100
CAC-5060 CC, G
CBC-✻✻ ✻✻BW,C
LGC-4010B C, P, I Reverse-flow
MCIDF-✻✻ ✻✻BV,C
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-7 CP-6-series Mechanical Reference