00196743-01 - Install Guide SIPLACE Explorer 2.7_en - 第11页

Ins ta llat i on and Con fi gur ati on Gu id e SI PLA CE Exp lo rer 1 Int rod uc tio n Edi tio n 03/201 0 E N 1. 3 Add it iona l Re mar ks 11 1.3 Additio nal Re marks SIPL A CE E x p lorer V ersion 2.7 ha s the following…

100%1 / 102
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.2 System Requirements Edition 03/2010 EN
10
SIPLACE Explorer V2.7 supports data from the following station software versions: 1
SW 704
SW 703
SW 702
SW 701
SW 605
SW 604
SW 603
SW 602
SW 601
SW 505
SW 407
SW 408
SW 101 for the CS and CF machine
The following version is supported but if problems should occur, you will need to update it to the
version shown above. 1
SW 503.04 SP 2: This version is only suitable if an update to SW 505.xx is not possible due to
hardware restrictions.
Installation and Configuration Guide SIPLACE Explorer 1 Introduction
Edition 03/2010 EN 1.3 Additional Remarks
11
1.3 Additional Remarks
SIPLACE Explorer Version 2.7 has the following restrictions: 1
When using MS Windows 7 with 64 Bit, you must install Adobe Reader 9.x manually otherwise
the online help cannot be opened via the websites. The Support Media DVD provides the
Adobe Reader 9.x in the "\TOOLS\ACROBAT READER" folder.
When upgrading from SIPLACE Explorer versions 2.2 and older to SIPLACE Explorer 2.7 the
Apache Tomcat web server has to be uninstalled first and afterwards be reinstalled from the
Support Media DVD. In doing so, you make sure that the correct Java version 1.6 is set for the
Apache Tomcat web server.
For all versions lower than SIPLACE Pro 7.0, OIS 7.0 and station software 703, SIPLACE Ex-
plorer 2.7 shows "N/A" instead of the PCB side on the Overview tab of the factory website.
For all versions lower than SIPLACE Pro 7.0, OIS 7.0 and station software 703, SIPLACE Ex-
plorer 2.7 shows "-" instead of the PCB side in the Current Recipe List table on the Produc-
tion Summary website.
Restriction due to NPI mode
SIPLACE Explorer V2.7 is unable to use data from SIS for boards which are marked as "SA"
(stand-alone). This means that the following information is not available for boards marked with
"SA":
Component name
Component shape
Feeder type
The following SMA pages show limited data due to the "Stand-alone" mode: 1
Pickup Reliability
Pickup Summary
–Reject Rate
Transition Log
Factory Layout:
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor five production lines with up to 20 stations.
Single Line Layout
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor one production line with up to 7 stations.
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.3 Additional Remarks Edition 03/2010 EN
12
For performance reasons, we recommend that you do not generate reports for all websites and
report types at once. Try to run the report generation at a time when there is no production op-
eration e.g. at the weekend.
From SIPLACE Explorer Version 2.0 SP1, the station GEM interface will no longer be sup-
ported i.e. data can not be recorded via the GEM interface with SIPLACE Explorer Version 2.2
or higher. If you need support for the GEM interface, please contact the SIPLACE Hotline.
The system time on the connected machines and that belonging to the SIPLACE Explorer must
be synchronized. SIPLACE machines require the installation of TimeSync, which is included
on the Support Media DVD provided with the delivery.
There is a special OIS status module realized in SIPLACE OIS. This OIS status module is
shown in the SIPLACE Explorer status module which matches the SEMI E10 status module.
This may lead to deviations in the states and status times shown between OIS and SIPLACE
Explorer. A direct comparison is therefore not possible.
The following restriction applies to platform I (S20, S23, F4, F5, F5HM) stations with dual con-
veyors:
The page Production Summary will display Unknown in the Current Recipe List table for
the 2nd conveyor lane. 1
Reason:
Platform I stations are unable to produce different recipes, even with dual conveyors. There-
fore, only one recipe will be loaded for the SIPLACE line. This recipe will then only be assigned
to conveyor lane I by SIPLACE Explorer. 1
When using the conveyor type "dual conveyor", the board counting function is subject to limi-
tations. It only records boards for conveyor lane 1. Boards produced on conveyor lane 2 are
not recorded. SIPLACE Explorer and OIS only show the boards for conveyor lane 1. The com-
ponents placed on the boards on conveyor lane 2 are assigned to the boards recorded for lane
1. This means that the number of consumed components shown is correct. This restriction ap-
plies to the following software versions: 407, 408, 502, 503, 504, 505.01, 505.02. The restric-
tion ceases to apply for version 505.03 onwards.
If partially placed boards are removed from the SIPLACE machine, without specifying this ter-
mination in the station software and removing them via the output conveyor, these boards will
not be recorded by the OIS and SIPLACE Explorer systems. In this case, the station software
is not able to generate the data set needed to record the boards. This restriction applies to all
available versions of the station software. If you need to terminate board placement, always
proceed as follows:
Terminate the board at the station software interface.
Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.