Site Preparation & Installation Section: 2 Page: 16 Revision Date: April 2005
Grounding
A dedicated equipment ground from the facility distribution panel for the oven is required to comply with Article
250 of the National Electrical Code. The equipment ground is necessary for the safety of personnel as well
for safe and reliable oven operation. All grounding and service wiring should be installed and tested by a
qualified licensed electrician.
Power Quality
The oven control systems do not condition the facility supplied power to the oven .
For proper operation, the power must be maintained at a "cleanliness level" of less than 10% of High
frequency (200V rise / microsecond) noise on the input voltage.
The AC voltage supplied to the oven must be + 10% of the stated voltage. (For example 220 VAC must
be between 198VAC and 242 VAC).
The voltage frequency must be within + 1% limit of the stated frequency.
For 3 Phase power, any line to neutral voltage must be within + 5% of the arithmetic mean of the three line
to neutral voltages.
Any and all damage, service and costs resulting from poorly conditioned facility power is solely the
responsibility of the customer.
Power Distribution
A dedicated facility electrical distribution panel is recommended. Avoid powering heavy duty, electrically noisy
equipment from the same panel as the oven; such as:
Heavy air conditioners
Elevators
Heaters
Office equipment
Fluorescent lights
Air ionizers
High current motors such as electric drills or water pumps
Welders
Placement equipment
Electromagnetic Fields
As with all electronically controlled equipment, the oven should be installed in an area not affected by
electromagnetic fields generated by other pieces of equipment.
Uninterruptable Power Supply Systems
Vitronics Soltec offers as and option, a UPS system for the oven which operates the oven conveyor, computer
/ control system and hood lifts for approximately five minutes after loss of facilities operating power. Consult
the purchase order for configuration. It is important to note that neither UPS option will operate the oven
heaters or cell fans.
Site Preparation & Installation Section: 2 Page: 17 Revision Date: April 2005
Nitrogen Supply (optional)
Oven Model 520 730 / 820 940 / 1030 1240
N
2
Process volume [low] CFH (M
3
/hr) 400 (12) 600 (17) 800 (23) 1000 (28)
N
2
Process volume [high] CFH (M
3
/hr) 1400 (40) 1600 (45) 1800 (51) 2000 (57)
N
2
volume [w/quick atmosphere purge] 2500 CFH (71 M
3
/hr)
Pressure regulated to 50-70 PSI (3.5-4.8 Bar)
Fitting size 3/8" Female National Pipe Thread (FNPT)
Supply pipe size 1/2"
Nitrogen purity [typical] * 99.9995%
Moisture content < 1 Volume Parts per Million (VPPM) @ 70
o
C
Oxygen content [typical] * < 5 Parts per Million (PPM)
* Multiple grades of Nitrogen are available. The following table is provided for reference to the incoming
Nitrogen supply.
%N2 Purity N
2
PPM O
2
PPM
99.0000% 990000 10000
99.5000% 995000 5000
99.9000% 999000 1000
99.9500% 999500 500
99.9900% 999900 100
99.9950% 999950 50
99.9990% 999990 10
99.9995% 999995 5
The actual atmosphere within the tunnel will vary depending
on oven configuration and process parameters.
Typical atmosphere performance will yield O
2
levels greater
than the source N
2
purity.
99.9999% 999999 1
The oven is equipped with a pressure regulator and gauge for control of the nitrogen supply.
Site Preparation & Installation Section: 2 Page: 18 Revision Date: April 2005
Compressed Air Supply
Pressure [Basic] regulated to 10-30 PSI (0.7-2.1 Bar)
Pressure [N
2
/Air Switching option] regulated to 50-70 PSI (3.5-4.8 Bar)
Volume 100 - 200 CFH, (2.8-5.6 M
3
/hr )
Fitting size 3/8" National Pipe Thread (NPT)
Supply pipe size 1/2"
The oven is equipped with a pressure regulator and gauge for control of the compressed air supply.
External Coolant Supply
For N2 ovens not equipped with Polar Cooling or Controlled Cooling options, must have a facility coolant
supply to the oven.
Temperature
20° C +/- 5° C
Flow rate 1.0 - 2.0 gpm (3.8-7.6 liter/min) minimum flow sensor trips at 0.5 gpm
Pressure (minimum)
sensor trips at 50 psig
2 Cooling zones 20 PSI (1.4 Bar)
3 Cooling zones 30 PSI (2.1 Bar)
4 Cooling zones 40 PSI (2.8 Bar)
Fitting size / type 3/8 FPT (Supply must be 3/8 MPT)
Coolant medium Supercool (Inhibited Propylene Glycol and distilled water mixture)
Alternative Coolant medium Pure distilled water
Note: flushing frequency increases 2-6X that of Supercool.
Caution: De-ionized water is NOT to be used (attacks brass and copper)
PH Neutral
Particulate Filtered to at least 100microns