00197623-03_VD_708.1_SP2_DE_EN - 第20页

Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 20 7 SIPLACE S oftware E nvironment 7.1 SIPLACE Pro P r ogramming S ystem Version 12. 1 The SIPLACE Pro programming system v ersion 12. 1 support…

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
19
6 Hardware Specifications
6.1 Supported Feeder Types
The following feeders are supported by the 708.1 SP2 station software version:
4 mm 104 mm X-feeder
2x8 mm X-feeder
16 mm XN-feeder
Surftape AX (8 mm, 12 mm, 16 mm)
LED feeder TE
LED feeder HS
SIPLACE Glue Feeder
TrayStack Feeder AX (X4i S on location 2 and 3 only)
SIPLACE JTF-S (X-series S and SX1/SX2 V2 only)
SIPLACE JTF-M (X-series S, X4i S micron and SX1/SX2 V2 only)
Arbitrary Carrier X (X-series only)
Conveyor Carrier X (X-series only)
Carrier X (XTH) (X2, X3, X4 on location 2 and 4 only)
Carrier SX (SX1/SX2 with Twin Head and CPP head only)
FFI feeders:
HanSan LED feeder
Top Engineering LED feeder
Data IO RoadRunners
IPTE Multi Stick Feeder:
IPTE multi stick 60 AX
IPTE multi stick XL80 AX
Stick feeder with X-adapter
Label feeder with X-adapter
Reject conveyor with X-adapter
Dip module for X-tables (LDU_X)
MTC2 (X2, X3, X4 on location 2 and 4, X2 S, X3 S, X4 S on location 2)
WPC5/WPC6 (SX1/SX2, X-series S on location 2)
SIPLACE Wafer Systems (CA-series only)
Splice sensor X-feeder
6.2 Camera Systems and Component Ranges
Detailed information about the used camera systems and component ranges for the placement
heads can be found in the respective machine specifications and/or User Manuals of the placement
machines.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
20
7 SIPLACE Software Environment
7.1 SIPLACE Pro Programming System Version 12.1
The SIPLACE Pro programming system version 12.1 supports the SIPLACE X-series, X-series S,
SX-series, DX-series and CA-series placement machines with the 708.1 station software version.
Compatible mode: SIPLACE Pro 11.x
NOTICE
For a detailed description of the programming system, see the SIPLACE Pro version
description and the online help system.
7.2 SIPLACE OIS Version 12.1
Software version 12.1 of the monitoring system SIPLACE OIS supports the SIPLACE X-series,
X-series S, SX-series, DX-series and CA-series placement machines.
Compatible mode: SIPLACE OIS 11.x
NOTICE
A detailed description can be found in the software description "Getting started with OIS"
and the online help system for OIS.
7.3 SIPLACE Setup Center Version 7.1
Software version 7.1 of the SIPLACE Setup Center supports the SIPLACE X-series, X-series S,
SX-series, DX-series and CA-series placement machines.
Compatible mode: SIPLACE Setup Center 6.x
NOTICE
A detailed description can be found in the software description "Getting started with
Setup Center" and the online help system for Setup Center.
7.4 SIPLACE Traceability Version 4.1 SP1
Software version 4.1 of SIPLACE Traceability supports the SIPLACE X-series, X-series S,
SX-series, DX-series and CA-series placement machines.
Compatible mode: SIPLACE Traceability 3.6
NOTICE
A detailed description can be found in the "Traceability User Guide".
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
21
8 Restrictions
X-Feeder
Because of the mirrored gantry configuration, the number of the available tracks on gantry 2 and 4
on the X4i, X4i S, SX4 and DX4 placement machines are restricted, not all of the tracks can be
reached by the placement heads. Feeders set on non-reachable tracks are deactivated
automatically.
Number of nozzle changer magazines
Because of the mirrored gantry configuration, the number of configurable nozzle changer
magazines on gantry 2 and 4 on the X4i, SX4 and DX4 placement machines is limited to 4
magazines.
Nozzle types
Nozzle types of the 4xx, 5xx, 8xx and 9xx series are not supported by the X4i, SX4 and DX4
placement machines.
Nozzle types of the 4xx, 5xx, 8xx, 9xx, 10xx, 11xx and 12xx series are not supported by the
CPP placement head.
PCB barcode
The PCB barcode is limited to 40 characters.
It is not recommended to scan the PCB barcode with the barcode reader and the PCB camera
simultaneously. If both scanning types are to be used within a use case on a machine, make
sure that both readers evaluate the same barcode label.
Fiducial patterns
Asymmetric fiducial patterns (e.g. triangles) can currently only be used if the board is processed at
an orientation of 0° in the machine.
X-table
An additional table fiducial is necessary for the gantries 2 and 4 on the X4i and SX4 placement
machines.
Twin Head/HFH
Twin Head/HFH are not supported on the X4i and DX4 placement machines.
Not vacuum pump compatible.
Not all pickup, dip and placement positions are accessible for both segments on the SX1/SX2
and SX4 placement machines.
CPP placement head
Restrictions for the X2, X3, X4, X4i and SX4 placement machines can be found in the
correspondent User Guides to the X-series and in the Version Description to SIPLACE Pro.
Not vacuum pump compatible.
Not supported on DX series placement machines.