00197623-03_VD_708.1_SP2_DE_EN - 第21页

Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 21 8 Restrictions X- Feeder Because of the m irrored gantry configuration, the number of the ava ilable tracks o n gantry 2 and 4 on the X4 i , X…

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
20
7 SIPLACE Software Environment
7.1 SIPLACE Pro Programming System Version 12.1
The SIPLACE Pro programming system version 12.1 supports the SIPLACE X-series, X-series S,
SX-series, DX-series and CA-series placement machines with the 708.1 station software version.
Compatible mode: SIPLACE Pro 11.x
NOTICE
For a detailed description of the programming system, see the SIPLACE Pro version
description and the online help system.
7.2 SIPLACE OIS Version 12.1
Software version 12.1 of the monitoring system SIPLACE OIS supports the SIPLACE X-series,
X-series S, SX-series, DX-series and CA-series placement machines.
Compatible mode: SIPLACE OIS 11.x
NOTICE
A detailed description can be found in the software description "Getting started with OIS"
and the online help system for OIS.
7.3 SIPLACE Setup Center Version 7.1
Software version 7.1 of the SIPLACE Setup Center supports the SIPLACE X-series, X-series S,
SX-series, DX-series and CA-series placement machines.
Compatible mode: SIPLACE Setup Center 6.x
NOTICE
A detailed description can be found in the software description "Getting started with
Setup Center" and the online help system for Setup Center.
7.4 SIPLACE Traceability Version 4.1 SP1
Software version 4.1 of SIPLACE Traceability supports the SIPLACE X-series, X-series S,
SX-series, DX-series and CA-series placement machines.
Compatible mode: SIPLACE Traceability 3.6
NOTICE
A detailed description can be found in the "Traceability User Guide".
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
21
8 Restrictions
X-Feeder
Because of the mirrored gantry configuration, the number of the available tracks on gantry 2 and 4
on the X4i, X4i S, SX4 and DX4 placement machines are restricted, not all of the tracks can be
reached by the placement heads. Feeders set on non-reachable tracks are deactivated
automatically.
Number of nozzle changer magazines
Because of the mirrored gantry configuration, the number of configurable nozzle changer
magazines on gantry 2 and 4 on the X4i, SX4 and DX4 placement machines is limited to 4
magazines.
Nozzle types
Nozzle types of the 4xx, 5xx, 8xx and 9xx series are not supported by the X4i, SX4 and DX4
placement machines.
Nozzle types of the 4xx, 5xx, 8xx, 9xx, 10xx, 11xx and 12xx series are not supported by the
CPP placement head.
PCB barcode
The PCB barcode is limited to 40 characters.
It is not recommended to scan the PCB barcode with the barcode reader and the PCB camera
simultaneously. If both scanning types are to be used within a use case on a machine, make
sure that both readers evaluate the same barcode label.
Fiducial patterns
Asymmetric fiducial patterns (e.g. triangles) can currently only be used if the board is processed at
an orientation of 0° in the machine.
X-table
An additional table fiducial is necessary for the gantries 2 and 4 on the X4i and SX4 placement
machines.
Twin Head/HFH
Twin Head/HFH are not supported on the X4i and DX4 placement machines.
Not vacuum pump compatible.
Not all pickup, dip and placement positions are accessible for both segments on the SX1/SX2
and SX4 placement machines.
CPP placement head
Restrictions for the X2, X3, X4, X4i and SX4 placement machines can be found in the
correspondent User Guides to the X-series and in the Version Description to SIPLACE Pro.
Not vacuum pump compatible.
Not supported on DX series placement machines.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
22
VHF P&P head
Supported on the SX1/SX2 V2 placement machine only.
Reduced air consumption with vacuum pump
No support for CPP placement heads and Twin Head.
Automatic tray feeding
The function is not supported on the X4i, SX4 and DX4 placement machines.
Dip module LDU_X
Parameterization in the component shape is not transferred to the LDU_X module. The
parameters have to be additionally set at the LDU_X module.
Reduced LDU_X performance, as maximum 2 A can be provided for each feeder. Therefore
the drives of the LDU_X module cannot reach the maximum possible acceleration.
LDU_X modules cannot be placed on any track of the X-table because of restrictions
concerning the accessibility with the twin head. The range of usable tracks for setting up
LDU_X modules is limited in SIPLACE Pro.
LDU_X module and manual tray cannot be placed together on one table on the machine types
X2, X3, X4, X4i and SX4.
The eSW of the LDU_X module can only be updated via notebook and serial interface.
Maximum component dimension: 45 x 45 mm. For TwinHead: squeegee cycle between the two
dipping processes, if the components on both head segments have to be dipped.
Setup verification is not supported with the LDU-X module.
Reachability of the LDU_X module in the X-, SX- and DX-series:
X2: Location 1 and 3 39.5 mm
Location 2 and 4 54 mm
X3: Location 1 22.5 mm
Location 3 39.5 mm
Location 2 and 4 54 mm
X4: Location 1 and 3 C&P20/CPP, 38 mm
Location 2 und 4 no restriction
X4i: All Locations 38 mm of 75 mm
SX1/2 and DX1/2:
Location 1 or 2 inner position: no restriction
outer position: half of the dipping area
SX4 All Locations 38 mm of 75 mm
Dipping with the C&P20A placement head is only possible with LDU_X as of function version 3.