00197623-03_VD_708.1_SP2_DE_EN - 第28页

Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 28 Counter for operating hours – If the pla cement machine is switch ed off abruptly or b y a direct "shutdow n" of the station softwar…

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
27
Brightness calibration of digital camera systems
Only conveyor lane 1 is used for the FCCS calibration.
No teaching of fiducial positions or structures on the calibrating jigs.
No machine stop at "track empty" errors in I-placement mode
If the Machine stop at pickup error option is deactivated, no machine stop errors caused by
pickup errors are transmitted to OIS and Explorer. In this case, the reporting of idle times
caused by pickup errors is not possible anymore.
If the placement machine does not stop it may happen that it in fact does not place anymore (it
waits for he feeders to be filled) but is not stopped either (e.g. boards might still be loaded).
This state is then displayed as "Producing" and not as stopped in OIS.
Adjustable minimum track width
The feature is only supported on the SX-series and DX-series placement machines.
In the Quad Lane conveyor mode there is only one adjustable value for each track pair.
Random setup for tray feeders
The feature only works in combination with SIPLACE Setup Center.
Automatic pin positioning with Smart Pin Support
The number of the support pins must not be greater than the number of pin garages.
No collision check in case of manual configurations on the Machine service and SIPLACE
service activity levels.
Support pins cannot be placed before all boards in the processing area have been produced
and unloaded from the machine. Loaded boards are blocked in the input section.
In case of barcode mode together with support pin positioning, a barcode change results in a
long changeover time, as the support pin positioning does not start until all boards have been
unloaded (except for the boards in the input section).
If Smart Pin Support is used on the X3 S, X4 S and X4i S placement machines the traveling
range is additionally limited.wird der Verfahrbereich zusätzlich eingeschränkt.
If a pin picker is installed on the X3 S, X4 S and X4i S placement machine, the maximum board
length is 410mm.
Smart Pin Support is not supported on the X2 S placement machine.
SIPLACE GlueFeeder feeder type
The following parameters can be set in SIPLACE Pro only:
Positions of the glue dots on the component
Glue dot diameter
Forced and unforced setup verfication are not supported.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
28
Counter for operating hours
If the placement machine is switched off abruptly or by a direct "shutdown" of the station
software console, the current value does not get stored in the EPROM on the I/O module. In
such cases the difference to the latest storage time gets lost (maximum 5 minutes deviation).
The counter for operating hours gets lost if two or more of the components I/O module, GCU or
station computer are exchanged.
Automatic recognition of the nozzle ID
Twin heads and SOKO nozzles of the C&P heads are not supported.
The scanned nozzle data gets lost at a machine reboot.
Flexible management of activity level rights
No message is displayed that a new activity level is active.
The rights can solely be changed via mouse / trackball (right-click). A change via touchscreen
is not possible.
X4i S placement machine
The traveling range in X direction is limited for the gantries 2 and 4 on the X4Si placement
machine.
TrayStack Feeder AX
The feeder is only supported on the X4i S placement machine and can be positioned on the
locations 2 and 3 only.
Only one Dip module LDU-X can be installed beside the feeder.
If 2 TrayStack Feeder AX are installed together with an LDU-X, the table has to be manually
selected in the Auto Configuration.
No nozzle changer support.
Stationary camera cannot be used.
CPP placement head supported only.
Feeder and placement heads are neither controlled in SIPLACE Pro nor in the station software.
Due to the hardware, the sequence oft he components (chain) cannot be warranted. Therefore,
setup verification with SIPLACE Setup Center cannot be performed.
After the machine has been rebooted or the feeder has been locked / unlocked, the feeder has
to be manually activated with the buttons on the feeder each time.
If the feeder is used without a reject conveyor, this may result in incomplete head cycles what
causes a reduced placement performance.
If there is no space to put back the component, it will be rejected.
Fine adjustment of the pitch at the feeder
For feeder types < 12mm, the current pitch in the feeder has to be set to > 4mm to achieve the
same functionality as on the operator panel of the feeder and to avoid incorrect settings for smaller
pitches.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
29
Fault-tolerant operation of the Twin Head
If Segment 1 has been deactivated or removed from the configuration, e.g. some single
placement positions might not be reachable because of the limited traveling range of Segment
2. The machine stops with a corresponding error message and the board cannot be finished.
No plausibility check will be performed in advance for a defined job or a board that enters the
machine.
Head calibration is not possible, if Segment 1 is deactivated or has been removed from the
configuration. If this is necessary, the functioning segment has to be installed on the position of
Segment 1.
No CAN communication with a segment that has been removed from the configuration.
No control of the Z-security for a segment that has been removed from the configuration.
A segment that has been removed from the configuration will not be actively secured, but will
generally be hold by the cylinder.The segment is held high enough, so that it will not come in
touch with placed components. If necessary, the nozzle has to be manually removed.
If a long/wide component is placed by the active segment, no check will be performed whether
a component is wiped off from the segment that has been removed from the configuration.
PCB barcode detection with Molex Traceability Pad
Barcode-controlled production is not supported.
Traceability is not possible until the barcode has been successfully read. Therefore, the
Traceability Pad should be placed / read in placement area 1 of the first placement machine in
the line. Only in this case, it is warranted that the Traceability information can be correctly
saved for all stations in the line.
No plausibility check if the placement position is to close to a component.
Barcodes can only be reliably measured by SIPLACE Vision if the component height (without
board warpage) at the position of the Traceability-Pad is < 1,5mm.
When the placement position is taught, the barcode / fiducial position will not be moved
correspondingly.
C&P20 M placement head
Supported on the CA-series and SIPLACE X4 S micron / X4i S micron placement machines only.
C&P20 P placement head
Supported on the X-series S placement machines only.
Twin VHF placement head
Supported on the SX1/SX2 V2 placement machine (with a higher positioned gantry) only.
No fast gantry exchange possible.
Must not be used together with the VHF P&P placement head on a machine.
SIPLACE JTF-S