00197623-03_VD_708.1_SP2_DE_EN - 第32页
Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 32 9 Corrected E rrors 708.1 SP2 Statio n Software The 708.1 SP2 stat ion software v ersion contains all e rror corrections of the previous 701. …
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
31
Individual barcode fiducials
– Barcode fiducials in trays are not supported.
– Barcode fiducials on the component underside are not supported because in this case the
barcode is read before the component is picked up.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
32
9 Corrected Errors
708.1 SP2 Station Software
The 708.1 SP2 station software version contains all error corrections of the previous 701.xx –
708.1 SP1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-114620601 The CAN card was not recognized during the first machine configuration.
D1-114934101 The production could not be started when a connected MTC was switched off.
D1-116350301 Sporadically LED components were placed separately and this reduced the
performance of the machine.
D1-116638601 Changes within the parameter settings for the Glue Feeder were not
transferred to the feeder.
D1-116695601 Sporadically, a nozzle could neither be put back into the magazine nor
rejected.
D1-114908602 A dirty or defective pressure regulation valve was not detected.
D17753-22701 Conveyor parameter Current at lifting table was not calculated correctly.
708.1 SP1 HF2
D1-114615401 During production the station software interface was suddenly no longer
responding. After restart it was ok.
D1-116251101 Feeder error messages were no longer included in the "EventLog" file.
708.1 SP1 HF1
D1-114500709 The C&P20 P component sensor calibration was not successful.
D1-114651365 eSW: The board could not be transported with the Advanced PCB Interface.
D1-114925901 The occupancy check for the MTC did not report any error message in case of
a faulty occupancy.
D1-115713001
D1-115727701
D1-115788501
The CPP component censor calibration was not successful; the height
reference run of the 2
nd
segment broke.
D1-115729601
D1-115739301
The temperature compensation could not be started although the temperature
was shown and the sensor running.
D1-115758001 eSW: The PCB barcode reader could not be configured.
Table 8-1: Corrected errors 708.1 SP2 station software version

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
33
708.1 SP1 Station Software Version
The 708.1 SP1 station software version contains all error corrections of the previous 701.xx –
708.1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-110371401 A nozzle got lost from the C&P20 P placement head during production but no
error message was displayed.
D1-112147342 The tape pocket measurement was too sensitive to lead deviations.
D1-112994843 Sporadically, the unknown HW error 0xF1 (DP axis) error message
was displayed.
D1-113336101 Some Reference Designators for some panels were missing in the traceability
system.
D1-114567701 Acknowledge of the buzzer was displayed even if the hardware was not
available on the machine.
D1-114583749 CA placement machine: the inspection of the chuck fiducials started although
it was deactivated.
D1-114679621 The software hung up when an error occurred during inkspot recognition.
D1-114940801
D17845-4407
There was no response from the MTC after a pickup error.
D1-115259384 After a product changeover, an unknown placement state (40020) was
reported endlessly for one component.
D1-115338650 Pitch too small error message was not reset after the manual correction
of the pitch.
D1-115304849 eSW: when production was continued after pressing the "stop" button and
opening the hood, the machine always executed a reference run.
708.1 HF04
D1-113666801 eSW: the transportation of the board into lane 1 or 2 via button on the GUI
failed if the cable of the advanced PCB interface was disconnected and
reconnected.
D1-114932601 eSW: there was a problem unloading a board if the length was between 930
and 985 mm.
D1-114932653 eSW: the conveyor lane width could not be adjusted because it had been set
too wide.
D1-114963801
D1-114935001
A collision of 2 gantries was reported.
D1-114999701 eSW: vacuum system: 30503 Supply pressure for pressure
control valve is missing
.
D1-115121901 Temperature compensation was not working correctly with C&P20 P
placement heads.
D1-115135201 eSW: the 3D-coplan module could not be measured. Windows hung up at the
first measurement.
D1-115160309 With HF3 some placement positions were out of the travel range.