00197623-03_VD_708.1_SP2_DE_EN - 第32页

Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 32 9 Corrected E rrors 708.1 SP2 Statio n Software The 708.1 SP2 stat ion software v ersion contains all e rror corrections of the previous 701. …

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
31
Individual barcode fiducials
Barcode fiducials in trays are not supported.
Barcode fiducials on the component underside are not supported because in this case the
barcode is read before the component is picked up.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
32
9 Corrected Errors
708.1 SP2 Station Software
The 708.1 SP2 station software version contains all error corrections of the previous 701.xx
708.1 SP1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-114620601 The CAN card was not recognized during the first machine configuration.
D1-114934101 The production could not be started when a connected MTC was switched off.
D1-116350301 Sporadically LED components were placed separately and this reduced the
performance of the machine.
D1-116638601 Changes within the parameter settings for the Glue Feeder were not
transferred to the feeder.
D1-116695601 Sporadically, a nozzle could neither be put back into the magazine nor
rejected.
D1-114908602 A dirty or defective pressure regulation valve was not detected.
D17753-22701 Conveyor parameter Current at lifting table was not calculated correctly.
708.1 SP1 HF2
D1-114615401 During production the station software interface was suddenly no longer
responding. After restart it was ok.
D1-116251101 Feeder error messages were no longer included in the "EventLog" file.
708.1 SP1 HF1
D1-114500709 The C&P20 P component sensor calibration was not successful.
D1-114651365 eSW: The board could not be transported with the Advanced PCB Interface.
D1-114925901 The occupancy check for the MTC did not report any error message in case of
a faulty occupancy.
D1-115713001
D1-115727701
D1-115788501
The CPP component censor calibration was not successful; the height
reference run of the 2
nd
segment broke.
D1-115729601
D1-115739301
The temperature compensation could not be started although the temperature
was shown and the sensor running.
D1-115758001 eSW: The PCB barcode reader could not be configured.
Table 8-1: Corrected errors 708.1 SP2 station software version
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
33
708.1 SP1 Station Software Version
The 708.1 SP1 station software version contains all error corrections of the previous 701.xx
708.1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-110371401 A nozzle got lost from the C&P20 P placement head during production but no
error message was displayed.
D1-112147342 The tape pocket measurement was too sensitive to lead deviations.
D1-112994843 Sporadically, the unknown HW error 0xF1 (DP axis) error message
was displayed.
D1-113336101 Some Reference Designators for some panels were missing in the traceability
system.
D1-114567701 Acknowledge of the buzzer was displayed even if the hardware was not
available on the machine.
D1-114583749 CA placement machine: the inspection of the chuck fiducials started although
it was deactivated.
D1-114679621 The software hung up when an error occurred during inkspot recognition.
D1-114940801
D17845-4407
There was no response from the MTC after a pickup error.
D1-115259384 After a product changeover, an unknown placement state (40020) was
reported endlessly for one component.
D1-115338650 Pitch too small error message was not reset after the manual correction
of the pitch.
D1-115304849 eSW: when production was continued after pressing the "stop" button and
opening the hood, the machine always executed a reference run.
708.1 HF04
D1-113666801 eSW: the transportation of the board into lane 1 or 2 via button on the GUI
failed if the cable of the advanced PCB interface was disconnected and
reconnected.
D1-114932601 eSW: there was a problem unloading a board if the length was between 930
and 985 mm.
D1-114932653 eSW: the conveyor lane width could not be adjusted because it had been set
too wide.
D1-114963801
D1-114935001
A collision of 2 gantries was reported.
D1-114999701 eSW: vacuum system: 30503 Supply pressure for pressure
control valve is missing
.
D1-115121901 Temperature compensation was not working correctly with C&P20 P
placement heads.
D1-115135201 eSW: the 3D-coplan module could not be measured. Windows hung up at the
first measurement.
D1-115160309 With HF3 some placement positions were out of the travel range.