Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 36 D1 - 113708001 The CPP placement head threw the co mponents into the wrong reject bin. D1 - 113723001 Machine cleaned t he nozzles too f reque…

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
35
D1-113982801 After the update from 708.0 to 708.1 all existing offset values in "manual
correction" were set to 0.
D1-114074881 After a restart of the machine gantry 1 reported the error that the z axis could
not be moved into a safe position.
D1-114100101
D1-114102501
The calibration of the head and the cameras failed.
D1-114416401 The machine stopped without error message when the height of the tray was
not correct.
D17710-4601 There were sporadic pauses when the head was identifying ink spots.
D17839-6712 Some components of location 2 and location 3 (for CPP head) were omitted.
D17936-3901 eSW: short tape handling in 8mm X feeder could not be activated.
D1-114557001 Sporadically, the error message 40034 CAUTION: Do not move
gantry! Head has lost a nozzle
was displayed.
D1-114422801 Taking out and in a board several times led to an unhandled exception error
when the board fiducials should be checked.
D1-113220101 The hourly performance in SIPLACE Explorer showed a high running time
value for a particular hour, but the PCB count was 0. There was no waiting or
blocked time during this hour.
708.1 HF01
D1-109834623 eSW: it was sporadically possible to change the pitch and the pickup position
on the feeder display although this was locked.
D1-111491609 Machine 2 restarted the station software; machine 1 was still in production.
Board was transferred to machine 2 and cancelled there.
D1-113015101 The machine stopped (because there was a component at the nozzle after
placement), but did not show any error.
D1-113386001
D1-113581429
D1-113718801
If you opened the cover there was no light in the machine.
D1-113392301 Error 40027: Support pin recognition failed.
The calibration did not function because of an error and the support pins could
not be used uncalibrated.
D1-113566601 The software hung up; there was an unhandled exception error on the screen.
D1-113567441
The board was marked as "not placed" in PA1 and PA2 (white circle instead of
green circle).
D1-113581209 Virtual keyboard could not be enabled or disabled anymore.
D1-113581249 After upgrade, the calibration for reference corner was missing.
D1-113632401
If value "0" was entered in the Cameras test illumination menu (gantry 4
with CPP head and IC camera), the software hung up.
D1-113649001
D1-113815401
D1-113839049
The number of the gantry or of the table insert was not shown within the
machine configuration.
D1-113654101 eSW: the machine referenced the axis after opening the cover.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
36
D1-113708001 The CPP placement head threw the components into the wrong reject bin.
D1-113723001
Machine cleaned the nozzles too frequently (nearly each third board). The
cycle time influence was too high.
D1-113847701
D1-114016201
D1-114020727
Error during system identification calibration: a gantry stopped and an
unknown hardware error was reported.
D17955-1001 Error message 30980 Measured angle outside tolerance.
D17973-1609
D1-105080241
Error message nozzle is unstable in the head after booting.
Table 8-2: Corrected errors 708.1 SP1 station software version
708.1 Station Software
The 708.1 station software version contains all error corrections of the previous 701.xx 708.0
versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-100201501 Not enough space to insert the pins in the Smart Pin Support service position.
D1-100463801 Segment 2 touched the component on Segment 1.
D1-104024701 Once you were in the drive through mode you could not change back.
D1-105553511 The conveyor system hung up without any error message.
D1-105631601 Disabling the pin picker did not force travel range calibration and zero point
correction.
D1-106099797
The CPP placement head was exchanged and production could continue. But
after a new job download, the 34304 error message (head on wrong position)
was presented.
D1-106141801 Reels were deleted unchecked.
D1-106578238
The GUI was not updated after a nozzle had been automatically rejected
during placement.
D1-106636901
After a hotfix upgrade on an X4i S placement machine, the gantry position on
gantry 4 could not be reached anymore.
D1-106688501 The setup of the table did not match the SIPLACE Pro setup.
D1-106744341 eSW: during production ISS was not responding.
D1-106824681 eSW: the nozzle changer could not be closed.
D1-107274901 Vacuum in holding circuit of the 2820 nozzle type was set to 0 mbar.
D1-107577901 eSW: the FCU disconnected the feeders 20 40.
D1-107889682 The reference point for PA1 was not displayed in the conveyor configuration.
D1-108277301 The lifting table did not move up when the SPS calibration was started.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
37
D1-108297901
eSW: the machine stopped with an unspecified hardware error and had to be
rebooted.
D1-108383021
The vacuum pump remained switched on even if it was switched off via the I/O
modules.
D1-108426841 eSW: the machine displayed X-axis error on gantry 4. After restart it was ok.
D1-108455001 The software did not start up completely and hung up during initialization.
D1-108496411
eSW: the single cores of the CPP placement head were changed but after a
firmware upgrade (automatic download) the head could not be detected.
D1-108559341
After having taught the pick-up position and sent the program, the head was
not able to pick up anymore.
D1-108559398 Sporadically, there was a placement offset on gantry 3.
D1-108677601
D1-110870801
eSW: Twin Head z-axis: counting error after head reconfiguration and
software update.
D1-108708401 The machine stopped for inspection.
D1-108750699 There was an unhandled exception.
D1-108751200 The field for placements was too small in the error statistics data.
D1-108776801 The nozzle changer calibration was not accepted during production.
D1-108800201 After pickup, the DP-axis did not move back and touched the conveyor.
D1-108838601 Error message 30001 internal software malfunction was displayed.
D1-109024401 After an unplanned shutdown, the pickup offset was set to 1 mm for all tracks.
D1-109282694 During production the pitch of the feeder changed automatically.
D1-109290501
The 31816 Error setting feeder display error was displayed at
every pickup from a 2x8 mm X-feeder.
D1-109291702
The GUI displayed Waiting until gantry stopped but nothing
happened; on the station software console an unhandled exception was
displayed.
D1-109325101 A SIPLACE X4 S placement machine could not be shut down regularly.
D1-109326037 There were too many restarts after eSW download.
D1-109367901
A machine stopped during the nightly endurance run without error message
(problems with the CIN card).
D1-109380901 There was a message that there was not enough power.
D1-109437541
It was not possible to measure the current sensor value for the C&P20 P
placement head.
D1-109449301
D1-111516325
The software hung up during the SMEMA check and the machine had to be
restarted.
D1-109780901
03015 component could not be placed due to wrong component sensor
values.
D1-109782901 After a reboot, the reference run did not work.