00197623-03_VD_708.1_SP2_DE_EN - 第36页
Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 36 D1 - 113708001 The CPP placement head threw the co mponents into the wrong reject bin. D1 - 113723001 Machine cleaned t he nozzles too f reque…

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
35
D1-113982801 After the update from 708.0 to 708.1 all existing offset values in "manual
correction" were set to 0.
D1-114074881 After a restart of the machine gantry 1 reported the error that the z axis could
not be moved into a safe position.
D1-114100101
D1-114102501
The calibration of the head and the cameras failed.
D1-114416401 The machine stopped without error message when the height of the tray was
not correct.
D17710-4601 There were sporadic pauses when the head was identifying ink spots.
D17839-6712 Some components of location 2 and location 3 (for CPP head) were omitted.
D17936-3901 eSW: short tape handling in 8mm X feeder could not be activated.
D1-114557001 Sporadically, the error message 40034 CAUTION: Do not move
gantry! Head has lost a nozzle
was displayed.
D1-114422801 Taking out and in a board several times led to an unhandled exception error
when the board fiducials should be checked.
D1-113220101 The hourly performance in SIPLACE Explorer showed a high running time
value for a particular hour, but the PCB count was 0. There was no waiting or
blocked time during this hour.
708.1 HF01
D1-109834623 eSW: it was sporadically possible to change the pitch and the pickup position
on the feeder display although this was locked.
D1-111491609 Machine 2 restarted the station software; machine 1 was still in production.
Board was transferred to machine 2 and cancelled there.
D1-113015101 The machine stopped (because there was a component at the nozzle after
placement), but did not show any error.
D1-113386001
D1-113581429
D1-113718801
If you opened the cover there was no light in the machine.
D1-113392301 Error 40027: Support pin recognition failed.
The calibration did not function because of an error and the support pins could
not be used uncalibrated.
D1-113566601 The software hung up; there was an unhandled exception error on the screen.
D1-113567441
The board was marked as "not placed" in PA1 and PA2 (white circle instead of
green circle).
D1-113581209 Virtual keyboard could not be enabled or disabled anymore.
D1-113581249 After upgrade, the calibration for reference corner was missing.
D1-113632401
If value "0" was entered in the Cameras – test illumination menu (gantry 4
with CPP head and IC camera), the software hung up.
D1-113649001
D1-113815401
D1-113839049
The number of the gantry or of the table insert was not shown within the
machine configuration.
D1-113654101 eSW: the machine referenced the axis after opening the cover.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
36
D1-113708001 The CPP placement head threw the components into the wrong reject bin.
D1-113723001
Machine cleaned the nozzles too frequently (nearly each third board). The
cycle time influence was too high.
D1-113847701
D1-114016201
D1-114020727
Error during system identification calibration: a gantry stopped and an
unknown hardware error was reported.
D17955-1001 Error message 30980 Measured angle outside tolerance.
D17973-1609
D1-105080241
Error message nozzle is unstable in the head after booting.
Table 8-2: Corrected errors 708.1 SP1 station software version
708.1 Station Software
The 708.1 station software version contains all error corrections of the previous 701.xx – 708.0
versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-100201501 Not enough space to insert the pins in the Smart Pin Support service position.
D1-100463801 Segment 2 touched the component on Segment 1.
D1-104024701 Once you were in the drive through mode you could not change back.
D1-105553511 The conveyor system hung up without any error message.
D1-105631601 Disabling the pin picker did not force travel range calibration and zero point
correction.
D1-106099797
The CPP placement head was exchanged and production could continue. But
after a new job download, the 34304 error message (head on wrong position)
was presented.
D1-106141801 Reels were deleted unchecked.
D1-106578238
The GUI was not updated after a nozzle had been automatically rejected
during placement.
D1-106636901
After a hotfix upgrade on an X4i S placement machine, the gantry position on
gantry 4 could not be reached anymore.
D1-106688501 The setup of the table did not match the SIPLACE Pro setup.
D1-106744341 eSW: during production ISS was not responding.
D1-106824681 eSW: the nozzle changer could not be closed.
D1-107274901 Vacuum in holding circuit of the 2820 nozzle type was set to 0 mbar.
D1-107577901 eSW: the FCU disconnected the feeders 20 – 40.
D1-107889682 The reference point for PA1 was not displayed in the conveyor configuration.
D1-108277301 The lifting table did not move up when the SPS calibration was started.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
37
D1-108297901
eSW: the machine stopped with an unspecified hardware error and had to be
rebooted.
D1-108383021
The vacuum pump remained switched on even if it was switched off via the I/O
modules.
D1-108426841 eSW: the machine displayed X-axis error on gantry 4. After restart it was ok.
D1-108455001 The software did not start up completely and hung up during initialization.
D1-108496411
eSW: the single cores of the CPP placement head were changed but after a
firmware upgrade (automatic download) the head could not be detected.
D1-108559341
After having taught the pick-up position and sent the program, the head was
not able to pick up anymore.
D1-108559398 Sporadically, there was a placement offset on gantry 3.
D1-108677601
D1-110870801
eSW: Twin Head z-axis: counting error after head reconfiguration and
software update.
D1-108708401 The machine stopped for inspection.
D1-108750699 There was an unhandled exception.
D1-108751200 The field for placements was too small in the error statistics data.
D1-108776801 The nozzle changer calibration was not accepted during production.
D1-108800201 After pickup, the DP-axis did not move back and touched the conveyor.
D1-108838601 Error message 30001 internal software malfunction was displayed.
D1-109024401 After an unplanned shutdown, the pickup offset was set to 1 mm for all tracks.
D1-109282694 During production the pitch of the feeder changed automatically.
D1-109290501
The 31816 Error setting feeder display error was displayed at
every pickup from a 2x8 mm X-feeder.
D1-109291702
The GUI displayed Waiting until gantry stopped but nothing
happened; on the station software console an unhandled exception was
displayed.
D1-109325101 A SIPLACE X4 S placement machine could not be shut down regularly.
D1-109326037 There were too many restarts after eSW download.
D1-109367901
A machine stopped during the nightly endurance run without error message
(problems with the CIN card).
D1-109380901 There was a message that there was not enough power.
D1-109437541
It was not possible to measure the current sensor value for the C&P20 P
placement head.
D1-109449301
D1-111516325
The software hung up during the SMEMA check and the machine had to be
restarted.
D1-109780901
03015 component could not be placed due to wrong component sensor
values.
D1-109782901 After a reboot, the reference run did not work.