Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 37 D1 - 108297901 eSW: the machin e stopped with an un specified hard ware error an d had to be rebooted. D1 - 108383021 The vacuum pump r emaine…

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
36
D1-113708001 The CPP placement head threw the components into the wrong reject bin.
D1-113723001
Machine cleaned the nozzles too frequently (nearly each third board). The
cycle time influence was too high.
D1-113847701
D1-114016201
D1-114020727
Error during system identification calibration: a gantry stopped and an
unknown hardware error was reported.
D17955-1001 Error message 30980 Measured angle outside tolerance.
D17973-1609
D1-105080241
Error message nozzle is unstable in the head after booting.
Table 8-2: Corrected errors 708.1 SP1 station software version
708.1 Station Software
The 708.1 station software version contains all error corrections of the previous 701.xx – 708.0
versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-100201501 Not enough space to insert the pins in the Smart Pin Support service position.
D1-100463801 Segment 2 touched the component on Segment 1.
D1-104024701 Once you were in the drive through mode you could not change back.
D1-105553511 The conveyor system hung up without any error message.
D1-105631601 Disabling the pin picker did not force travel range calibration and zero point
correction.
D1-106099797
The CPP placement head was exchanged and production could continue. But
after a new job download, the 34304 error message (head on wrong position)
was presented.
D1-106141801 Reels were deleted unchecked.
D1-106578238
The GUI was not updated after a nozzle had been automatically rejected
during placement.
D1-106636901
After a hotfix upgrade on an X4i S placement machine, the gantry position on
gantry 4 could not be reached anymore.
D1-106688501 The setup of the table did not match the SIPLACE Pro setup.
D1-106744341 eSW: during production ISS was not responding.
D1-106824681 eSW: the nozzle changer could not be closed.
D1-107274901 Vacuum in holding circuit of the 2820 nozzle type was set to 0 mbar.
D1-107577901 eSW: the FCU disconnected the feeders 20 – 40.
D1-107889682 The reference point for PA1 was not displayed in the conveyor configuration.
D1-108277301 The lifting table did not move up when the SPS calibration was started.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
37
D1-108297901
eSW: the machine stopped with an unspecified hardware error and had to be
rebooted.
D1-108383021
The vacuum pump remained switched on even if it was switched off via the I/O
modules.
D1-108426841 eSW: the machine displayed X-axis error on gantry 4. After restart it was ok.
D1-108455001 The software did not start up completely and hung up during initialization.
D1-108496411
eSW: the single cores of the CPP placement head were changed but after a
firmware upgrade (automatic download) the head could not be detected.
D1-108559341
After having taught the pick-up position and sent the program, the head was
not able to pick up anymore.
D1-108559398 Sporadically, there was a placement offset on gantry 3.
D1-108677601
D1-110870801
eSW: Twin Head z-axis: counting error after head reconfiguration and
software update.
D1-108708401 The machine stopped for inspection.
D1-108750699 There was an unhandled exception.
D1-108751200 The field for placements was too small in the error statistics data.
D1-108776801 The nozzle changer calibration was not accepted during production.
D1-108800201 After pickup, the DP-axis did not move back and touched the conveyor.
D1-108838601 Error message 30001 internal software malfunction was displayed.
D1-109024401 After an unplanned shutdown, the pickup offset was set to 1 mm for all tracks.
D1-109282694 During production the pitch of the feeder changed automatically.
D1-109290501
The 31816 Error setting feeder display error was displayed at
every pickup from a 2x8 mm X-feeder.
D1-109291702
The GUI displayed Waiting until gantry stopped but nothing
happened; on the station software console an unhandled exception was
displayed.
D1-109325101 A SIPLACE X4 S placement machine could not be shut down regularly.
D1-109326037 There were too many restarts after eSW download.
D1-109367901
A machine stopped during the nightly endurance run without error message
(problems with the CIN card).
D1-109380901 There was a message that there was not enough power.
D1-109437541
It was not possible to measure the current sensor value for the C&P20 P
placement head.
D1-109449301
D1-111516325
The software hung up during the SMEMA check and the machine had to be
restarted.
D1-109780901
03015 component could not be placed due to wrong component sensor
values.
D1-109782901 After a reboot, the reference run did not work.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
38
D1-109862101 There were pickup problems for 0201 components at one location.
D1-109891701 There was an error message during shutdown of the machine.
D1-109921701
eSW: Siplace Advanced Board – incompatible interface between station
software versions 707 and 708.
D1-109921741 eSW: the board was not transferred from PA1 to PA2.
D1-109928675
D1-109928627
After having taught the pickup position the GUI disappeared.
D1-110015401 Test bench inspection: the z-axis did not reach the target position.
D1-110056326
The feeding axis target position was outside the range on certain trays of the
MTC when the last component was in the top right corner.
D1-110116301
The new "orientation check by operator" option checked all trays even if they
were not verified (because they were empty).
D1-110263201 The software disappeared when the "watchdog timer" was selected.
D1-110280401
The following warning was displayed on the GUI: Communication problem
with the processor of the axis control of y axis at gantry 1.
D1-110364201 Error message position out of range at job change.
D1-110375701 3D-sensor calibration did not work.
D1-110379151 There was a 3D vision error (vision communication was interrupted).
D1-110405601
During production, the 32602 The software has stopped unexpectedly. Shut
down Windows, then restart the station error message was displayed.
D1-110413901
D17862-3607
The filling levels of the packaging units could not be edited anymore.
D1-110414201 Unhandled exception during machine mapping.
D1-110558301
The "Shield" component (118 x 48 mm) was rotated 180° after pickup during
teaching.
D1-110563301
A long gripper (110 mm) on Segment 2 was touched by the black cover plate
of Segment 1 and rejected.
D1-110631301
eSW: the tables 3 and 4 were not displayed on the GUI although they were
mounted.
D1-110632301 It was not possible to calibrate the z-axis on gantry 1/segment 1.
D1-110804201
An automatic bug report could not be created on the GUI after the 40034 error
(only 4 digits allowed for error number).
D1-110826705
eSW: during the nozzle change the Overlapping of star and z axis,
gantry 1, CP20a
error occurred.
D1-110855747
After a restart, the machine could not be moved to the service position of the
star and DP-axes.
D1-110857487 Nozzle scan was not in the center what led to a high reject rate.
D1-110864601
eSW: there was an unexpected restart of the subsystem after having
downloaded the eSW of the feeder.