Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 38 D1 - 109862101 There were pickup pr oblems for 02 01 components at one location. D1 - 109891701 There was an error me ssage during s hutdown o…

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
37
D1-108297901
eSW: the machine stopped with an unspecified hardware error and had to be
rebooted.
D1-108383021
The vacuum pump remained switched on even if it was switched off via the I/O
modules.
D1-108426841 eSW: the machine displayed X-axis error on gantry 4. After restart it was ok.
D1-108455001 The software did not start up completely and hung up during initialization.
D1-108496411
eSW: the single cores of the CPP placement head were changed but after a
firmware upgrade (automatic download) the head could not be detected.
D1-108559341
After having taught the pick-up position and sent the program, the head was
not able to pick up anymore.
D1-108559398 Sporadically, there was a placement offset on gantry 3.
D1-108677601
D1-110870801
eSW: Twin Head z-axis: counting error after head reconfiguration and
software update.
D1-108708401 The machine stopped for inspection.
D1-108750699 There was an unhandled exception.
D1-108751200 The field for placements was too small in the error statistics data.
D1-108776801 The nozzle changer calibration was not accepted during production.
D1-108800201 After pickup, the DP-axis did not move back and touched the conveyor.
D1-108838601 Error message 30001 internal software malfunction was displayed.
D1-109024401 After an unplanned shutdown, the pickup offset was set to 1 mm for all tracks.
D1-109282694 During production the pitch of the feeder changed automatically.
D1-109290501
The 31816 Error setting feeder display error was displayed at
every pickup from a 2x8 mm X-feeder.
D1-109291702
The GUI displayed Waiting until gantry stopped but nothing
happened; on the station software console an unhandled exception was
displayed.
D1-109325101 A SIPLACE X4 S placement machine could not be shut down regularly.
D1-109326037 There were too many restarts after eSW download.
D1-109367901
A machine stopped during the nightly endurance run without error message
(problems with the CIN card).
D1-109380901 There was a message that there was not enough power.
D1-109437541
It was not possible to measure the current sensor value for the C&P20 P
placement head.
D1-109449301
D1-111516325
The software hung up during the SMEMA check and the machine had to be
restarted.
D1-109780901
03015 component could not be placed due to wrong component sensor
values.
D1-109782901 After a reboot, the reference run did not work.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
38
D1-109862101 There were pickup problems for 0201 components at one location.
D1-109891701 There was an error message during shutdown of the machine.
D1-109921701
eSW: Siplace Advanced Board – incompatible interface between station
software versions 707 and 708.
D1-109921741 eSW: the board was not transferred from PA1 to PA2.
D1-109928675
D1-109928627
After having taught the pickup position the GUI disappeared.
D1-110015401 Test bench inspection: the z-axis did not reach the target position.
D1-110056326
The feeding axis target position was outside the range on certain trays of the
MTC when the last component was in the top right corner.
D1-110116301
The new "orientation check by operator" option checked all trays even if they
were not verified (because they were empty).
D1-110263201 The software disappeared when the "watchdog timer" was selected.
D1-110280401
The following warning was displayed on the GUI: Communication problem
with the processor of the axis control of y axis at gantry 1.
D1-110364201 Error message position out of range at job change.
D1-110375701 3D-sensor calibration did not work.
D1-110379151 There was a 3D vision error (vision communication was interrupted).
D1-110405601
During production, the 32602 The software has stopped unexpectedly. Shut
down Windows, then restart the station error message was displayed.
D1-110413901
D17862-3607
The filling levels of the packaging units could not be edited anymore.
D1-110414201 Unhandled exception during machine mapping.
D1-110558301
The "Shield" component (118 x 48 mm) was rotated 180° after pickup during
teaching.
D1-110563301
A long gripper (110 mm) on Segment 2 was touched by the black cover plate
of Segment 1 and rejected.
D1-110631301
eSW: the tables 3 and 4 were not displayed on the GUI although they were
mounted.
D1-110632301 It was not possible to calibrate the z-axis on gantry 1/segment 1.
D1-110804201
An automatic bug report could not be created on the GUI after the 40034 error
(only 4 digits allowed for error number).
D1-110826705
eSW: during the nozzle change the Overlapping of star and z axis,
gantry 1, CP20a
error occurred.
D1-110855747
After a restart, the machine could not be moved to the service position of the
star and DP-axes.
D1-110857487 Nozzle scan was not in the center what led to a high reject rate.
D1-110864601
eSW: there was an unexpected restart of the subsystem after having
downloaded the eSW of the feeder.

Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
39
D1-110888501 Error 42416 came up with HF1 on some machines.
D1-110889301
eSW: gantry 1 was waiting until stopped; the machine hung and had
to be rebooted.
D1-110889341
eSW: the vacuum was not sufficient, all DPs got disabled and there was no
more communication with the star.
D1-110988210 Synchronous dual conveyor mode ran asynchronous.
D1-110991201
Nach einem behobenen Transportfehler blinkte die weiße Lampe an Stellplatz
1 immer noch und der Status konnte nicht zurückgesetzt werden.
D1-111020501
An offset correction for the SST47 was not possible, as manually set values
were not used.
D1-111491101 Gantry 3 was waiting above the placement position and nothing happened.
D1-111551707
After a restart, the 30554 Subsystem is not responding error was
issued by the WPC6 loading axis although the WPC functioned correctly.
D1-111551756 After a restart of the machine the 41304 error was displayed.
D1-111839301 Error 32602: the machine stopped during the centering of the nozzles.
D1-112035501
The software hung up due to the disconnection of control software port 49000
in localhost.
D1-84084601
The display of the sticks (2 on one feeder) on the linear feeder was not
correct.
D1-86607201 The station software did not support the Unicode font in all cases.
D1-87545901
D1-108277201
Risk of collision between tray feeder with high components and CPP
placement head.
D1-92074901 After the manual tray had been refilled, the fiducials were not remeasured.
D1-93537601 On a SIPLACE SX2 V2 placement machine (Gantry 1: Twin Head, Gantry 2:
C&P12 placement head) the real performance was appr. 12 % lower as the
optimized performance.
D1-97080801 The pickup location was displayed in red in the main view.
D1-97968449 A component could not be placed due to a timeout error for the DP-axis.
D17651-2207 After a product change, the feeder settings were not downloaded.
D17687-10301
The sensor rail on track 2 touched the board support when the conveyor width
was enlarged.
D17723-4901
OIS 11.2 displayed the "waiting time" state for PA1 but it should be "blocked
time".
D17739-5083 eSW: the X-feeder had no power at track 29.
D17753-12301 No error history regarding transport errors was logged at the station.
D17758-4401 Sporadically, the software hung up and the machine had to be rebooted.
D17768-2301 Machine stopped without error message during normal processing.
D17791-1277 The station software GUI was hidden and could not be operated.