00197623-03_VD_708.1_SP2_DE_EN - 第40页

Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 40 D17843 - 2007 GUI freezed and hu ng up. D17935 - 201 When the LBO option w as used on an SI PLACE X3 placement machine, two placement position…

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
39
D1-110888501 Error 42416 came up with HF1 on some machines.
D1-110889301
eSW: gantry 1 was waiting until stopped; the machine hung and had
to be rebooted.
D1-110889341
eSW: the vacuum was not sufficient, all DPs got disabled and there was no
more communication with the star.
D1-110988210 Synchronous dual conveyor mode ran asynchronous.
D1-110991201
Nach einem behobenen Transportfehler blinkte die weiße Lampe an Stellplatz
1 immer noch und der Status konnte nicht zurückgesetzt werden.
D1-111020501
An offset correction for the SST47 was not possible, as manually set values
were not used.
D1-111491101 Gantry 3 was waiting above the placement position and nothing happened.
D1-111551707
After a restart, the 30554 Subsystem is not responding error was
issued by the WPC6 loading axis although the WPC functioned correctly.
D1-111551756 After a restart of the machine the 41304 error was displayed.
D1-111839301 Error 32602: the machine stopped during the centering of the nozzles.
D1-112035501
The software hung up due to the disconnection of control software port 49000
in localhost.
D1-84084601
The display of the sticks (2 on one feeder) on the linear feeder was not
correct.
D1-86607201 The station software did not support the Unicode font in all cases.
D1-87545901
D1-108277201
Risk of collision between tray feeder with high components and CPP
placement head.
D1-92074901 After the manual tray had been refilled, the fiducials were not remeasured.
D1-93537601 On a SIPLACE SX2 V2 placement machine (Gantry 1: Twin Head, Gantry 2:
C&P12 placement head) the real performance was appr. 12 % lower as the
optimized performance.
D1-97080801 The pickup location was displayed in red in the main view.
D1-97968449 A component could not be placed due to a timeout error for the DP-axis.
D17651-2207 After a product change, the feeder settings were not downloaded.
D17687-10301
The sensor rail on track 2 touched the board support when the conveyor width
was enlarged.
D17723-4901
OIS 11.2 displayed the "waiting time" state for PA1 but it should be "blocked
time".
D17739-5083 eSW: the X-feeder had no power at track 29.
D17753-12301 No error history regarding transport errors was logged at the station.
D17758-4401 Sporadically, the software hung up and the machine had to be rebooted.
D17768-2301 Machine stopped without error message during normal processing.
D17791-1277 The station software GUI was hidden and could not be operated.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
40
D17843-2007 GUI freezed and hung up.
D17935-201
When the LBO option was used on an SIPLACE X3 placement machine, two
placement positions were omitted automatically. This was caused by a very
high component.
Table 8-3: Corrected errors 708.1 station software version
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
41
10 Important Terms and Abbreviations
ACT Accuracy Check Tool
CA4 Machine type of the Chip Assembly (CA)-series with 4 gantries
CA4 eWLP Machine type of the Chip Assembly (CA)-series with 4 gantries
and WLFO (customer project, no release for series production)
C&P Collect & Place
CPP Collect & Place & Pick & Place
DC Dual Conveyor
DX1/DX2 Machine type with 1 or 2 gantries
DX4 Machine type with 4 gantries
EDIF Electronic Design Interchange Format
eWLP embedded Wafer Level Process
FCCS Field Camera Calibration System
GCU Gantry Control Unit (new electronic concept for X4i)
GUI Graphical User Interface
HCU Head Control Unit (new electronic concept for X4i)
HFH High Force Head
HW Hardware
MTC Matrix Tray Changer
OIS Operator Information System
PA Processing area
PCB Printed circuit board
SC Single Conveyor
SC SIPLACE Setup Center (external setup control system)
SW Software
SWS SIPLACE Wafer System
SX1/SX2 Machine type with 1 or 2 gantries
SX3 Machine type with 3 gantries
SX4 Machine type with 4 gantries
TH Twin Head
TH HF Twin Head High Force
Twin VHF Very High Force Twin Head
VC Vision computer
VCU Vision Control Unit
VHF P&P Very High Force Pick&Place
WLFO Wafer Level Fan-Out, Chip Assembly process
WPC Waffle Pack Changer
X2/X2 S Machine type with 2 gantries