SM482PLUS_Maintenance(Eng_Ver2.7).pdf - 第29页
Chap ter 2 Inspe ction It ems fo r Main t e nanc e Multi -Func tional Placer SM482PLUS Maintenance Handbo ok 2-4 W eekly Inspections Inspection It ems for Maint enanc e

Chapter 2
Inspection Items for Maintenance
Multi-Functional Placer
SM482PLUS Maintenance Handbook
2-3
Weekly Inspections
Check-up List
Maintenance
Cycle
Reference
Time
required
Period No Inspection Item Measures Tools
Weekly
W-1 Head Fly Camera Lens Clean Air spray, Ethyl alcohol, Cotton swab 5 Minutes
W-2 Head Mirror Clean
Air spray, Ultra-fine fiber cloth, Ethyl
alcohol
5 Minutes
W-3 Solenoid Valve Inspect and replace 2 years
Contact C/S for
replacement
20 Minutes
W-4 Head Vacuum Filter Inspect and replace 6 months
Contact C/S for
replacement
30 Minutes
Setting the replacement period for parts
ㆍ The part inspection and replacement interval shall be set up based on the specified operation environment.
ㆍ If the conditions for operation are poor, the part inspection and replacement interval may be reduced.
ㆍ In the above table, C/S means our designated C/S company or our overseas local agents.
ㆍ Consumables should be purchased for a fee, regardless of the warranty period.
Weekly Inspections

Chapter 2
Inspection Items for Maintenance
Multi-Functional Placer
SM482PLUS Maintenance Handbook
2-4
Weekly Inspections
Inspection Items for Maintenance

Chapter 2
Inspection Items for Maintenance
Multi-Functional Placer
SM482PLUS Maintenance Handbook
2-5
Monthly Inspections (1/2)
Check-up List
Maintenance
Cycle
Reference
Time
required
Period No Inspection Item Measures Tools
Monthly
M-1 Head Spindle Clean
Cleaning liquid, Air gun, Ultra
fine fiber cloth
30 Minutes
M-2 Conveyor Sensor / Fiducial Mark Inspect and clean
Cleaning liquid, Cotton Swab,
Ultra fine fiber cloth
10 Minutes
M-3 Cover Cooling Fan Inspect and clean
Crosshead screwdriver,
Vacuum cleaner
10 Minutes
M-4 Cover Cooling Fan Filter Inspect and clean Vacuum cleaner 6months 15 Minutes
Setting the replacement period for parts
ㆍ The part inspection and replacement interval shall be set up based on the specified operation environment.
ㆍ If the conditions for operation are poor, the part inspection and replacement interval may be reduced.
ㆍ In the above table, C/S means our designated C/S company or our overseas local agents.
ㆍ Consumables should be purchased for a fee, regardless of the warranty period.
Monthly Inspections (1/2)