2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.5 Energy Level after Switching Off Main Switch Edition 05/00
50
 (QHUJ\/HYHODIWHU6Z L WFK LQJ2 II0DLQ6ZLW FK
DANGER
The placement system is powered with 3 x 204 VAC (USA version) 3 x 230 VAC, 3 x 380 VAC,
3 x 400 VAC respectively 3 x 415 VAC ± 5 %, 50/60 Hz mains voltage. This means that parts of
the system carry potentially lethal voltages - even when switched off at the main switch. Death,
serious injury and considerable damage may result if these placement systems are handled
incorrectly.
Å Always follow the applying accident prevention rules and DIN regulations (particularly
EN 60204, part 1).
Å The guards over the control and servo units must ONLY be opened by appropriately qualified
and trained personnel.
Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 05/00 2.5 Energy Level after Switching Off Main Switch
51
.(<
.(<
(1) Main switch
(2) Service socket behind protective door
(3) Compressed air unit
(4) Servo unit
(5) Measuring unit in servo unit
(1) Main switch
(2) Control unit
(3) Power supply unit ± 12 VDC
(4) Power supply unit ± 15 VDC
(5) Power supply unit + 5 VDC/+ 24 VDC
(6) Power supply unit + 5 VDC/+ 50 VDC
2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.5 Energy Level after Switching Off Main Switch Edition 05/00
52
 3ODFHPHQW6\VWHP6ZLWFKHG2IIDWWKH0 DLQ6Z LWFK EXW6 WLOO &RQQHFWHG
The following table specifies the voltages of modules when the placement system is switched off
at the main switch, but still remains connected to the mains supply.
DANGER
The following components still carry potentially lethal voltages even if the main switch is switched
off:
Cable connection terminals 1, 3, and 5 of S1 main switch,
Z1 mains filter,
BU1 service socket,
F1 automatic circuit breaker for the service socket.
The color of all single wires, which still carry potentially lethal voltages even if the main switch
is switched off is brown.
0RGXOH 9ROWDJH
Mains filter Z1
Terminals L1, L2, L3
3 x 204 V AC
3 x 230 V AC
3 x 380 V AC
3 x 400 V AC
3 x 415 V AC
Service socket BU1
115 V AC
130 V AC
220 V AC
230 V AC
240 V AC
Circuit breaker F1
115 V AC
130 V AC
220 V AC
230 V AC
240 V AC