HS50的结构及原理 - 第70页
3 Test Equipment Adjustment Instructions S IPLACE HS-50 3.9 Gauge for Z-Axis Edition 05/00 70 *DXJHIRU=$ [LV $ SSOLFDWLRQ The gauge is used for the a djustm ent of t he z-axis stop on th e top.

Adjustment Instructions SIPLACE HS-50 3 Test Equipment
Edition 05/00 3.8 Calibration Tool for the Collect & Place Head
69
&DOLEUDWLRQ7RROIRUWKH&ROOHFW3ODFH+HDG
Gauge for the star, item no: 00326164-01
Parallel pin 1.4 mm, item no: 00326160-01
Parallel pin 1.5 mm, item no: 00326161-01
Parallel pin 1.6 mm, item no: 00326162-01
Parallel pin 1.3 mm item no: 00326163-01
Distance gauge, item no: 00325445-01
0HDVXULQJWRROV 8VDJH
Gauge for the star Adjustment of zero point correction star
Parallel pin 1.4 mm
Adjustment of distance between read head of dp - station to glass
pane of sleeve
Parallel pin 1.5 mm
Parallel pin 1.6 mm
Parallel pin 1.3 mm Adjustment of distance light barrier z-axis bottom to sleeve
Distance gauge Adjustment of the distance between valve plunge and star

3 Test Equipment Adjustment Instructions SIPLACE HS-50
3.9 Gauge for Z-Axis Edition 05/00
70
*DXJHIRU=$[LV
$SSOLFDWLRQ
The gauge is used for the adjustment of the z-axis stop on the top.

Adjustment Instructions SIPLACE HS-50 4 Overview Voltages
Edition 05/00 4.1 Position of Components
71
2YHUYLHZ9ROWDJHV
3RVLWLRQRI&RPSRQHQWV
The figure below shows the position of the components which create and distribute the supply volt-
ages needed to operate the system:
– Power supply unit (Item 1)
– Main distributor (Item 2)
– Control unit (Item 3)
– Servo unit (Item 4)
A
A
1
3
4
2