Fitting the Vacuum Pump 3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-x x] on Machines Kxxx / L xxx / Mxxx Preparatory Steps Vacuum Pump Vakuumpumpe 101 Variant 2 1. Fixt ure points f or connect ion unit …

100%1 / 134
Fitting the Vacuum Pump
Preparatory Steps 3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Ma-
100 Vacuum Pump Vakuumpumpe
3.3.3
3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx / Lxxx / Mxxx
Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx /
Lxxx / Mxxx
Variant 1
Remove the two screws (1).
Remove the plate (2).
The electrical connection unit is installed in the location 2
area.
Remove the cover from the power supply.
The plate is clipped into the machine frame. Take
hold of the loop (1) and pull it out.
On machines from N001, remove the cover (2) from
the machine base.
Fitting the Vacuum Pump
3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Machines Kxxx / Lxxx / Mxxx Preparatory Steps
Vacuum Pump Vakuumpumpe 101
Variant 2
1. Fixture points for connection unit
2. Connector X102
3. Cable X103
The vacuum pump connection unit [03079949-xx] is
fitted to a mounting rail. Use the screws provided to
fix the vacuum pump connection unit to the two posi-
tions shown here (1).
After installing the pump, connect the cable
[03079997-xx] for the vacuum pump power supply to
terminal X106 of the connection unit (1).
Connect the cable [03087337-xx] upgrade kit (cable:
vacuum pump connection unit) between X102 for the
transformer unit and X105 for the vacuum pump con-
nection unit (2).
Connect the cable [03072544-xx] (cable: vacuum
pump control), which is already in the machine, to
X103 for the connection unit (3).
Transformer unit (without terminals) (1)
Fitting the Vacuum Pump
Preparatory Steps 3.3.3 Fitting the Vacuum Pump Connection Unit SX1/2 [03079949-xx] on Ma-
102 Vacuum Pump Vakuumpumpe
1. x103
2. x102
3. Cable [03087337-xx]
4. Cable [03079997-xx]
Use the Klettostar tape to fix the connection vacuum
pump unit SX1/SX2 [03079949-xx] (1) in the front half
of the plate.
NOTICE
New connection units
Newer versions of the connection units need to be disassembled from the mounting plate first!
NOTICE
Cable for the vacuum pump connection unit
The cable for the vacuum pump connection unit [03087337-xx] is no longer needed from ma-
chine number N001.