00196614-03_AI_Vakuumpumpe_SXDX12_de_en - 第111页
Fitting the Vacuum Pump 3.4.4 Connecting the Exhaust Tube ID100 [03087599-xx] Installing the Vacuum Pump Vacuum Pump Vakuumpumpe 111 3.4.4 3 . 4 . 4 C o n n e c t in g t h e E x h a u s t T u b e I D 1 0 0 [ 0 3 0 8 7 5 …

Fitting the Vacuum Pump
Installing the Vacuum Pump 3.4.2 Connecting the Vacuum Hoses to the Distributor Block
110 Vacuum Pump Vakuumpumpe
3.4.2
3.4.2 Connecting the Vacuum Hoses to the Distributor Block
Connecting the Vacuum Hoses to the Distributor Block
3.4.3
3.4.3 Fitting the Air Outlet Conduit [03079527-xx] Under the Machine
Fitting the Air Outlet Conduit [03079527-xx] Under the Machine
► Connect the vacuum hoses to the distributor block:
⇨ Hose 1 m vacuum pump SX12 [03090005-xx]
⇨ Hose 2 m vacuum pump SX12 [03090006-xx]
► For a complete head assembly, use the connections
in the row (1) or all angle connection in the row (2).
► If you are only connecting one head, close the con-
nections in the free row with dummy plugs.
Air outlet conduit before installation
The air outlet conduit must be placed under the machine
if the exhaust air is to be guided outside properly.
1. Slot
2. Screw and nib engage
3. Mounting plate
4. Stop position of pump
► The air outlet conduit is pushed under the pump dur-
ing installation, so that the screw fixed with adhesive
to the wedge and the nib on the base plate of the
pump (2) engage with one another. The wedge is
screwed to the mounting plate through the slots on
the left and right (1). (Screws: ISO4762-M8x40-A2-
70 [03042589-xx])

Fitting the Vacuum Pump
3.4.4 Connecting the Exhaust Tube ID100 [03087599-xx] Installing the Vacuum Pump
Vacuum Pump Vakuumpumpe 111
3.4.4
3.4.4 Connecting the Exhaust Tube ID100 [03087599-xx]
Connecting the Exhaust Tube ID100 [03087599-xx]
► Lift the vacuum pump and push in the air outlet con-
duit. It will engage into its end position on the assem-
bly plate.
► Screw the air outlet conduit on the left and right to the
fixture points shown before.
► You may want to have a flashlight ready to see your
workplace better.
► Fit the spanner wrench provided to the vacuum
pump, as shown in the diagram.
► Adjust the exhaust tube to a length of 120 cm.
► Position the exhaust tube onto the connecting piece
and run the hose along the side of the machine base
and out of the machine.
► Fasten the hose with a hose clamp Ideal Maxi W1
[03090050-xx] to position (1).

Fitting the Vacuum Pump
Installing the Vacuum Pump 3.4.5 Closing the Installation Location
112 Vacuum Pump Vakuumpumpe
3.4.5
3.4.5 Closing the Installation Location
Closing the Installation Location
► After fitting the pump, close the installation point with
the "cover plate assembly / P001" [03088818-xx].