00196614-03_AI_Vakuumpumpe_SXDX12_de_en - 第118页
Fitting the Vacuum Pump Converting Placement Heads 3.5.2 Conversion for C&P12 118 Vacuum Pump Vakuumpumpe

Fitting the Vacuum Pump
3.5.2 Conversion for C&P12 Converting Placement Heads
Vacuum Pump Vakuumpumpe 117
Work to be performed
C&P12 head
1. Head interface and head adapter
2. Head plate
3. Adapter plate (between head plate and head)
4. Screws fastening the head to the adapter plate
5. Vacuum generator
1. Compressed air hoses
2. Vacuum generator
► Replace the existing vacuum generator with the "vac-
uum generator for vacuum pump DLM2
[03012076-xx].
1
1
2
Fitting the Vacuum Pump
Converting Placement Heads 3.5.2 Conversion for C&P12
118 Vacuum Pump Vakuumpumpe

Fitting the Vacuum Pump
3.5.2 Conversion for C&P12 Final Work
Vacuum Pump Vakuumpumpe 119
3.6
3.6 Final Work
Final Work
► Fit the cover over the vacuum pump.
► Install the used tape chute.
Compone nt Supply - Manual Tables - Fitting Pr otections - Color Version
► If you have removed the table height adjustment and the calibration tool holder, refit these.
► If you have opened the cover on the cable duct and left it up during the conversion work, close it
again now.
► Refit the center cover on the distributor and fix into place.
► Dock the component trolleys onto the SX machines.
► Re-insert the manual table into DX machines.
► Switch the machine on.
► Open the compressed air shut-off valve.
► Push the pneumatic unit into the machine.
► Close all doors.
► Switch the machine on at the main switch.
Manual tables only:
WARNING!
There is a risk of injury on manual tables without the two
protections.
► Fit the two protections:
– Protection waste chute DX1/2 left [03094519-xx]
– Protection waste chute DX1/2 right [03094522-
xx]
CAUTION
Switch-on preconditions
Before switching on, perform the following checks to prevent injuries or serious damage to
property:
Make sure of the following before you switch the compressed air supply back on:
► Check that all hose connections are correctly assigned. Make sure that no compressed air
can get into a vacuum hose.
► Check that all conditions for switch-on of the vacuum pump and connected placement ma-
chine have been fulfilled. Read the corresponding operation manuals for more information.
► Make sure that the vacuum pump is always switched on before the machine.