00196614-03_AI_Vakuumpumpe_SXDX12_de_en - 第78页

Introduction Abbreviations 1.3.5 SIPLACE on the World Wide Web (WWW) 78 Vacuum Pump Vakuumpumpe 1.5 1 . 5 A b b r e v ia t io n s Abbreviations Abbreviations Desc ription CO Component COT Chang eover table COT-i Chan geo…

100%1 / 134
Introduction
1.3.5 SIPLACE on the World Wide Web (WWW) Staff Qualifications and Training
Vacuum Pump Vakuumpumpe 77
1.3.5
1.3.5 SIPLACE on the World Wide Web (WWW)
SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE
®
homepage at http://www.siplace.com.
You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the
SIPLACE User Group
. Here you can call up spe-
cial information about our placement systems e.g.
Technical documentation,
Technical information,
Spare parts lists etc.
Registration for the user group is very simple:
Click on the Register link.
Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with USER ID and password.
1.4
1.4 Staff Qualifications and Training
Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op-
eration and maintenance of automatic placement systems and add-on devices and are suitably qualified,
e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord-
ance with normal safety standards.
Have received first aid training.
Introduction
Abbreviations 1.3.5 SIPLACE on the World Wide Web (WWW)
78 Vacuum Pump Vakuumpumpe
1.5
1.5 Abbreviations
Abbreviations
Abbreviations Description
CO Component
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P20/A/M Collective term for C&P20, C&P20 A and C&P20 M
C&P20/A/M/P Collective term for C&P20, C&P20A, C&P20M and C&P20P
C&P6, CP6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP12 and/or CP6
DC Dual conveyor with two lanes
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
FHE Fast Head Exchange
ID Intermediate distributor
ID1, ID2 Intermediate distributor 1, intermediate distributor 2
MTC Matrix Tray Changer
NC Nozzle Changers
PA, PA1, PA2 Placement area, Placement area 1, Placement area 2
PCB Board
P&P Pick&Place
QC Quad lane conveyor with four lanes
SC Station computer
SC Single conveyor with one lane
SCS Single Core Solution
TH TwinHead
VS Vision system type
WPC Wafflepack changer
WPC4/5/6 Wafflepack changer version 4/5/6
Brief Description
Vacuum Pump Vakuumpumpe 79
2
2 Brief Description
Brief Description
Every C&P head has a separate vacuum generator that supplies the holding and placement circuit with
the vacuum that it needs.
The vacuum generator for the placement heads works according to the Venturi principle. In combination
with a vacuum pump, the compressed air consumption can be significantly reduced for the SpeedStar
(C&P20 A/P) head. The ongoing operating costs are reduced according to the energy costs.
NOTICE
C&P20 A/P heads
The vacuum pump used here can supply a maximum of two C&P20 A/P heads.
The description of the following tasks and information for which the C&P20 A head is used
as example also apply to the C&P20 P. Any relevant differences are mentioned explicitly.
NOTICE
C&P20 P heads generally with vacuum
If the C&P20 P head is to be used on a machine in compressed air mode (Venturi), the head
must be converted with the "Conversion kit compressed air operation CP20 P" [03106765-xx].
For a conversion reversal from compressed air mode back to vacuum pump mode, you need
the aperture ring "Orifice plate cpl. CP20p [03108716-xx].
NOTICE
Conversion
If you need to convert a gantry from C&P20 A/P to TwinHead or CPP head, you must re-estab-
lish the original compressed air supply for this gantry. Conversion reversal must be performed
on all assemblies for this gantry.
NOTICE
Partial conversion
Partial conversion of the pneumatic unit, for example, involving disconnection of the gantry hos-
es (additional vacuum hoses) during compressed air operations, can lead to serious placement
machine malfunctions.
NOTICE
Retrofitting
If you need to convert a gantry from TwinHead or CPP head to C&P20 A/P head with vacuum
function, you must retrofit the vacuum equipment for this gantry.
NOTICE
Compressed air operation
If you operate a C&P20 A/P or a C&P12 (DLM) head which has been converted for vacuum
operation at a gantry with compressed air, this could lead to serious damage to the placement
head if the silicon hoses to the segments should loosen.