00196614-03_AI_Vakuumpumpe_SXDX12_de_en - 第83页
Brief Description Tools and equipment required Vacuum Pump Vakuumpumpe 83 Installation kit for vacuum pump 2.4 2 . 4 T o o ls a n d e q u ip m e n t r e q u ir e d Tools and equipment required ▪ Spanner wrench, size 10 ▪…

Brief Description
Scope of Delivery
82 Vacuum Pump Vakuumpumpe
2.3
2.3 Scope of Delivery
Scope of Delivery
For the C&P20 P or the C&P6/12, one kit must be ordered per head.
Conversion kit for vacuum pump operation C&P12 [00119796-xx]
The vacuum generator is completely assembled on delivery.
Conversion kit for vacuum pump operation C&P20 [00119790-xx]
Retrofit kit vacuum pump SX1/SX2 [00519862-xx]
Assembly kit for vacuum pump in SX1/SX2
Quantity Item no. Designation
1 03046348-xx Aperture ring, cpl. C+P20
3 03042543-xx ISO 4762 - M3x10-A2-70
3 00316904-xx DIN 125-A 3.2-140HV-A2
Quantity Item no. Designation
1 03079949- xx Connection unit for vacuum pump SX1/2
1 03087337- xx Cable: connection unit for vacuum pump
1 03090581-xx Compact connector, 2-conductor 222-412
1 03113103-xx Piping vacuum pump SX1/2
1 03090043-xx Spanner wrench SW36
1 03079997- xx Cable: power supply for vacuum pump
2 03092492-xx Thread sealant Loctite 55
1 03113098-xx Klettostar Loop and Hook 20cm
Quantity Item no. Designation
1 03075664-xx Welding-assembly for support sheet
1 03079501- xx Support plate for vacuum pump
4 03042574-xx ISO 4762 - M6x20-A2-70
2 03087279-xx Sliding film
1 03069679- xx Becker VX4 25 vacuum pump
2 00386753-xx Cable clamp type Hellermann Kd 12.5
2 03042551-xx ISO 4762 - M4x8-A2-70
2 03007604-xx ISO 7089 - 4 - 200 HV
1 03079527-xx Air outlet conduit
1 03087208- xx Mounting plate
2m 03087599- xx Exhaust tube ID100
2 03053793-xx Push-in connector QS-12-10
1 03090050-xx Hose clamp Ideal Maxi W1
1 03082844-xx ISO10642 - M6 x 16-A2-70

Brief Description
Tools and equipment required
Vacuum Pump Vakuumpumpe 83
Installation kit for vacuum pump
2.4
2.4 Tools and equipment required
Tools and equipment required
▪ Spanner wrench, size 10
▪ Spanner wrench SW 36 [03090043-xx] (included in conversion kit)
The spanner wrench is needed for replacing the filter insert during service work.
▪ Allen key set
▪ Set of Philips screwdrivers
▪ Diagonal cutters
▪ Hose pliers
▪ Flashlight
▪ Tension belt
▪ Loctite 55 [03092492-xx]
▪ Service manual for your machine
▪ Maintenance manual for your machine
▪ Enlist the help of a second person when installing the vacuum pump.
▪ Have a pallet truck and a suitable pallet ready for use. (See also section "3.4.1 Inserting the Pump
into the Machine" [ ➙ 109])
Quantity Item no. Designation
3 03038816-xx Push-in L-fitting QS-1/2-10
1 03086336-xx Distributor block
1 03070370-xx Vacuum filter F10
1 03004775-xx Locking screw R3/4 St+NBR
2 03080578-xx Push-in L-fitting QSL-1/2-12
3 03081051-xx Push-in L-fitting QSL-1/2-10
1 03088251-xx Reducing nipple G1 - G3/4
2 03038435-xx Double nipple, detachable G3/4 Ms
1 03093668-xx Double nipple G3/4 brass
1 03088818-xx Cover plate cpl. / P001

Brief Description
Prerequisites
84 Vacuum Pump Vakuumpumpe
2.5
2.5 Prerequisites
Prerequisites
Machines with vacuum pump have a higher energy and a lower compressed air consumption than ma-
chines without a vacuum pump (see "2.2 Energy and Compressed Air Consumption" [ ➙ 81]).
Adjust the power and compressed air supply to the relevant specifications.
The C&P20 A head must be converted for use with a vacuum pump using the vacuum pump operation
conversion kit for C&P20 A [00119790-xx] (see "3.5.1 Conversion for C&P20A/P" [ ➙ 113]).
The C&P12 head (DLM) must be converted for the use with a vacuum pump using the 119796 vacuum
pump operation retrofit kit for C&P12 (see "3.5.2 Conversion for C&P12" [ ➙ 116]).
2.6
2.6 Restrictions
Restrictions
The TwinHead and CPP placement heads are not compatible with vacuum pump operation.
The pressure control valve needs to be operated with compressed air for all placement heads.
The TwinHead is generally supplied via the pressure control valve. Conversion to vacuum mode is there-
fore not possible.
In CPP heads, the holding circuit is not designed for vacuum operation.
The placement heads must be refitted according to the machine configuration.
▪ The C&P20A/M for compressed air mode is delivered with vacuum generator.
▪ The C&P20 P is delivered with a aperture ring for vacuum pump mode.
NOTICE
Return cylinder unable to move out
Do not convert the pneumatic supply for the gantry affected to vacuum mode. If the compressed
air supply for this head is converted to vacuum operation, the return cylinder will be unable to
move out and the Z axis will remain in its top position.
NOTICE
Aperture rings
The aperture ring cpl. CP20p [03108716-xx] and the aperture ring cpl. C+P20 [03046348-xx]