00196614-03_AI_Vakuumpumpe_SXDX12_de_en - 第98页
Fitting the Vacuum Pump Preparatory Steps 3.3.2 Prefitting the Vacuum Pump 98 Vacuum Pump Vakuumpumpe 3.3.2.6 3 . 3 . 2 . 6 I n s t a llin g a n d A d ju s t in g t h e L e a k a g e V a lv e Installing and Adjusting the…

Fitting the Vacuum Pump
3.3.2 Prefitting the Vacuum Pump Preparatory Steps
Vacuum Pump Vakuumpumpe 97
3.3.2.5
3.3.2.5 Preparing and Connecting the Distributor Block
Preparing and Connecting the Distributor Block
1. Four o'clock position
► Screw the filter insert [03077677-xx] onto the first half
of the double nipple and into the pump. First apply
Loctite 55 to the threaded connection.
► Correctly position the filter. The connecting piece
must point to 4 o'clock (1).
► Tighten the nuts with the "spanner wrench SW36"
[03090043-xx].
► (1) Screw a double nipple G3/4 brass [03093668-xx]
into the filter. First apply Loctite 55 to the threaded
seal.
1. 3x push-in L-fitting QS-1/2-10 [03038816-xx]
2. 3x push-in L-fitting QSL-1/2-10 [03081051-xx]
► Screw the three 10er angle connections to the distrib-
utor block [03086336-xx].
► Use the M36 open-jawed spanner [03090043-xx]
provided to fix the distributor block in the position
shown (1).

Fitting the Vacuum Pump
Preparatory Steps 3.3.2 Prefitting the Vacuum Pump
98 Vacuum Pump Vakuumpumpe
3.3.2.6
3.3.2.6 Installing and Adjusting the Leakage Valve
Installing and Adjusting the Leakage Valve
The leakage valve is closed completely with two placement heads in vacuum mode.
If only one placement head is to be operated with the vacuum pump, the valve must be opened by a ½
rotation.
3.3.2.7
3.3.2.7 Placing the Vacuum Pump onto the Slide
Placing the Vacuum Pump onto the Slide
► Dismantle the distribution block from the vacuum
pump.
► Unscrew a Festo screw joint (1).
► Mount the ½ inch (1) to 1 inch (2) adapter and the
Becker vacuum valve (3).
Vacuum pump slide
1. Fixture points for cable clamps
2. Nibs for subsequent fixture of slide to exhaust air duct
3. 4 fixture points for vacuum pump

Fitting the Vacuum Pump
3.3.2 Prefitting the Vacuum Pump Preparatory Steps
Vacuum Pump Vakuumpumpe 99
1,2 fixture points for vacuum pump
► Connect the vacuum pump [03069679-xx] to the car-
riage [03077380-xx] as shown in the photo.
► Fix the vacuum pump to the carriage (at positions (1)
and (2) and on the opposite side). Use the type
ISO4762-M5x30-A2-70 screws [03042565-xx] for
this.
1 Fixture point for cable clamps
2, 3 Guiding the power cable upwards
► Fit the two cable clamps onto the power cable.
► Fix the two cable clamps to position 1. In each case,
place a washer between the cable clamp
[00386753-xx] and the screw (ISO4762-M4x8-A2-70)
[03042551-xx].
► Run the power cable upwards (2) and over the
pump (3).