00198351-01_AI_Location 2 Upgrade Kit_E by SIPLACE_en - 第28页
2 Installation of Location 2 Upgrade Kit 2.5 Optional Assembly Instructions E by SIPLACE Location 2 Upgrade Kit 04/2017 28 2.5 Optional ► You can unfasten the four M8x10, dismantle the Side bracket B right [03109832- xx]…

Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
2 Installation of Location 2 Upgrade Kit
2.4 Installing the E-series Tape Cutter [03105585-xx]
27
► Fasten the two M8x50 cap screws on each side (left & right) to the machine frame.
► Loosen the M10x100 screw after the tape cutter is securely fastened.

2 Installation of Location 2 Upgrade Kit
2.5 Optional
Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
28
2.5 Optional
► You can unfasten the four
M8x10, dismantle the Side
bracket B right [03109832-
xx] and the Side bracket B
left [03109810-xx].
► Keep and mount them onto
the machine base frame.

Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
2 Installation of Location 2 Upgrade Kit
2.6 Installing the E-Series Empty Tape Duct (ETD)
29
2.6 Installing the E-Series Empty Tape Duct (ETD)
► Install the Waste Tape Chute. The Waste
tape chute has two riveted key-hole side
plates.
► Mount the waste tape chute using the four
M4x10 screws on to the tape cutter side
holder.