00198351-01_AI_Location 2 Upgrade Kit_E by SIPLACE_en - 第30页

2 Installation of Location 2 Upgrade Kit 2.6 Installing the E-Series Empty Tape Duct (ETD) Assembly Instructions E by SIPLACE Location 2 Upgrade Kit 04/2017 30 Installing the ETD Cassette 25 mm ► Insert the ETD into the …

100%1 / 34
Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
2 Installation of Location 2 Upgrade Kit
2.6 Installing the E-Series Empty Tape Duct (ETD)
29
2.6 Installing the E-Series Empty Tape Duct (ETD)
Install the Waste Tape Chute. The Waste
tape chute has two riveted key-hole side
plates.
Mount the waste tape chute using the four
M4x10 screws on to the tape cutter side
holder.
2 Installation of Location 2 Upgrade Kit
2.6 Installing the E-Series Empty Tape Duct (ETD)
Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
30
Installing the ETD Cassette 25 mm
Insert the ETD into the machine frame, guided by the pre-assembled self-clinching pilot pin on
the mounting bracket
Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
2 Installation of Location 2 Upgrade Kit
2.6 Installing the E-Series Empty Tape Duct (ETD)
31
Fasten the two screws
M5x10 on the left and right
ETD side mounting
bracket.