■ Administrator Functions ◘ Teaching the Package File PS Series Owner’s Manual 3—49 back Figure 3-4 1: Vacuum swit ch on the Laser tab (or Shuttle/Options ta b). (PS588 Gantr y Window shown.) 6b. Click the Pick Pos butto…

100%1 / 234
Operation Administrator Functions
3—48 Data I/O • 981-0424-002
back
3g. If the new values for X and Y are greater than ±5, press Yes and
repeat Step 3e to Step 3f.
If the new values for X and Y are less than ±5, press No.
4. Teach Vibrator 2 locations—
4a. At the Gantry window, click Vib2.
4b. Repeat these steps (1b–3g) for Vibrator 2.
Set R-value the same as Vibrator 1.
Setting Values for the Shuttle
1. Positioning the Shuttle
1a. Exit the Gantry Window.
1b. At the System Window click Shuttle/Options.
1c. Click Home.
1d. After the head stops moving, click the first Go button (adjacent
to the Ped 2 Load Pos).
1e. Click Exit. Then at the System Window, click Gantry.
2. Teach locations—
2a. At the Gantry Window, click Shu to move the PNP head to the
marking shuttle.
2b. If necessary, adjust the location so the probe is centered on Ped-
estal 2. Use the X and Y-axis arrows (along the bottom and right
side of the black work area) to center the probe on the pedestal.
2c. Click Save and Yes.
3. Placing a device on Shuttle 2—
3a. Click Park to move the PNP head to the Park location.
3b. Click the Shuttle/Options tab. (In some machines/configurations,
this tab may say Laser.)
3c. Turn the Vacuum button to ON if it is not already.
3d. Manually place a device on shuttle Pedestal 2.
3e. Click the Actuator tab.
4. Set Z & R values—
4a. Click Shu.
4b. Click ZAutoFind and Yes.
4c. Click Rotate button.
4d. Type the desired rotation into the rotate field and press Enter on
the keyboard. See Rotation Values on page 3-43 for more informa-
tion.
4e. Save and click Yes.
5. Remove the device from Shuttle 2—
5a. Click Park.
5b. Click the Shuttle/Options tab.
5c. Turn the Vacuum button to OFF.
5d. Manually remove the device from shuttle Pedestal 2.
5e. Click the Actuator tab.
6. Accurately centering the probe —
6a. Click label Shu to move the probe to the marking shuttle.
Administrator Functions Teaching the Package File
PS Series Owner’s Manual 3—49
back
Figure 3-41: Vacuum switch on the Laser tab (or Shuttle/Options tab).
(PS588 Gantry Window shown.)
6b. Click the Pick Pos button to lower the probe.
6c. If necessary, adjust the location so the probe is centered on Ped-
estal 2. Use the X and Y-axis arrows (along the bottom and right
side of the black work area) to center the probe on the pedestal.
6d. Click Save and Yes.
6e. Click the Pick Pos button again to raise the probe.
Setting Values for Tape-Input
With the chip feeder installed and the pocket pitch set correctly:
1. Advance the chip feeder—
1a. On the chip feeder control panel, while pressing and holding the
center button, press the forward button. The carrier tape
advances one guide hole. Advance the carrier tape until the cen-
ter of the device aligns with the pick point mark.
Figure 3-42: A chip feeder mounted on a PS388.
For more information, the
Operator Guide that
came with your Chip
Feeder.
Operation Administrator Functions
3—50 Data I/O • 981-0424-002
back
2. Teach locations—
2a. At the Gantry window, click Tape to move the probe to the tape
input pick position.
2b. If necessary, adjust the location so the probe is centered on pick
point. Use the X and Y-axis arrows (along the bottom and right
side of the black work area) to center the probe on the pick
point.
2c. Click Save and Yes.
2d. Click Z AutoFind (to set the vertical distance to the device) and
then Yes to save the value.
3. Set Rotation at Tape Input—
3a. Click Rotate button.
3b. Type the desired rotation into the rotate field and press Enter on
the keyboard. See Rotation Values on page 3-43 for more informa-
tion.
3c. Save and click Yes.
3d. Click X,Y AutoFind. When the results appear, verify that the new
values for X and Y are less than ±5. If so, click No (to keep the
previous values).
If new values are greater than ±5, click Yes to use these new val-
ues. Then recheck (by clicking X, Y AutoFind again).
This completes the process of teaching the Package File.
Errors
Axis Limit Error
During the process of teaching the Package File, you will be directing
the PNP head to move to various locations inside the work envelope.
If the PNP head is directed to move beyond its X-axis or Y-axis limits,
you will see a red error button.
To resolve axis limit errors:
1. Record error message—
1a. Note what item was being taught when the error appeared, such
as Programmer 5 or Tray 1 or Tube 2.
1b. Click the Error button to display the error message.
X,Y AutoFind sends the
probe to the vision cam-
era and compares the
device image with the
reference vision file.