Operation Operator Functions
3—12 Data I/O • 981-0424-002
back
.
Figure 3-13: TaskLink displays job transfer progress.
6. When job setup is complete, TaskLink displays the calculated
checksum and confirms launching the AH500 software if Dis-
play Checksum option is checked in TaskLink. Click Yes.
.
Figure 3-14: Click Yes to launch AH500 Software (if message displays).
7. On the AH500 main window under Current Job, the name of the
job just loaded is displayed.
Operator Functions Running a Job on PS Systems
PS Series Owner’s Manual 3—13
back
.
Figure 3-15: The AH500 main window opens with a job loaded and its
name displayed (arrow). (PS588 shown.)
(Optional) Preselecting Programmers
The PS288 & PS388 can be configured with up to four FlashCORE
programmers. The PS588 can be configured with up to 12 program-
mers, which can be a mix of FlashCORE and Universal OPTIMA pro-
grammers.
To improve efficiency, shut off programmers that are not used for a
particular job as follows:
1. On the AH500-PS System main window, click Preselect Program-
mers. Refer to Figure 3-15.
2. Click I (green side) of the Unlock Cnf button to allow changes.
3. For each programmer, click I (green side) of the button to enable
it or the O (red side) to disable it. See Figure 3-16.
Note: If a programmer does not have a Socket Adapter, or an incor-
rect Socket Adapter is installed, the programmer will automatically
be disabled.
Operation Operator Functions
3—14 Data I/O • 981-0424-002
back
Figure 3-16: Preselecting programmers. In this image, programmers 1
and 2, are disabled. (PS588 shown.)
4. Lock the configuration again only if you wish to keep this setting
the next time the system is turned on: click the O (red) side of the
Lock Cnf button
Adjust Socket Opener Ribs
[PS288, PS388, and Optima on PS588 only]
1. Adjust the Socket Opener Ribs—
Note: It is necessary to adjust the Socket Opener after installing
different Socket Adapters.
1a. On the Power Panel, turn the main air valve OFF. (It is off when
the lock rings line up: some models.)