2 Replacing spare parts
2.6 Contact module
Service Manual SIPLACE MeasurementFeeder X 02/2020 21
2.6.1 Removing the contact module
Place the MeasurementFeeder onto a table.
Loosen the two cross head countersunk screws
which are holding the contact module cover using
a 3mm Allen key.
Remove the contact module cover in direction of
arrow.
Loosen the four cross head countersunk screws
which are holding the protective plate using a
2.5mm Allen key.
Remove the protective plate.
Loosen the two Allen screws on the top of the
contact module using a 3mm Allen key.
2 Replacing spare parts
2.6 Contact module
22 Service Manual SIPLACE MeasurementFeeder X 02/2020
Disconnect the connector form the contact mod-
ule.
To remove the contact module from the measure-
ment feeder, push contact module in direction of
arrow.
2.6.2 Fitting the contact module
Insert the contact module back to the Measure-
mentFeeder.
2 Replacing spare parts
2.6 Contact module
Service Manual SIPLACE MeasurementFeeder X 02/2020 23
Connect the contact module to the connector.
Put a drop of Loctite 243 on the two marked
screws (M3X12 Allen screw, 03042544).
Tighten the two screws on the top of the contact
module.
Align the protective plate.
Tighten the four cross head countersunk screws
(ISO7046-2 M2.5X6, 03023228-xx) to hold the
protective plate.
Put the contact module cover on the top of the contact
module as shown.
Tighten the two cross head countersunk screws
(ISO7046-2 M3X6, 03023238-xx) to hold the con-
tact module cover.