00198532-01_SM_MeasurementFeeder_EN - 第23页

2 Replacing spare parts 2.6 Contact module Service Manual SIPLACE MeasurementFeeder X 02/2020 23 ► Connect the contact module to the connector. ► Put a drop of Loctite 243 on the two marked screws (M3X12 Allen screw, 030…

100%1 / 30
2 Replacing spare parts
2.6 Contact module
22 Service Manual SIPLACE MeasurementFeeder X 02/2020
Disconnect the connector form the contact mod-
ule.
To remove the contact module from the measure-
ment feeder, push contact module in direction of
arrow.
2.6.2 Fitting the contact module
Insert the contact module back to the Measure-
mentFeeder.
2 Replacing spare parts
2.6 Contact module
Service Manual SIPLACE MeasurementFeeder X 02/2020 23
Connect the contact module to the connector.
Put a drop of Loctite 243 on the two marked
screws (M3X12 Allen screw, 03042544).
Tighten the two screws on the top of the contact
module.
Align the protective plate.
Tighten the four cross head countersunk screws
(ISO7046-2 M2.5X6, 03023228-xx) to hold the
protective plate.
Put the contact module cover on the top of the contact
module as shown.
Tighten the two cross head countersunk screws
(ISO7046-2 M3X6, 03023238-xx) to hold the con-
tact module cover.
2 Replacing spare parts
2.7 Measurement board
24 Service Manual SIPLACE MeasurementFeeder X 02/2020
2.7 Measurement board
Required spare part
Fig.6: Measurement board cpl
Feeder module Item no. Designation
MeasurementFeeder X 03210586-xx Measurement board cpl
Required tools
Flat-bladed screwdriver
Phillips screwdriver
Spanner, size 5mm
Loctite 243