00198532-01_SM_MeasurementFeeder_EN - 第26页

2 Replacing spare parts 2.7 Measurement board 26 Service Manual SIPLACE MeasurementFeeder X 02/2020 2.7.2 Fitting the measurement board ► Align the measurement board to the Measure- mentFeeder. ► Put a drop of Loctite 24…

100%1 / 30
2 Replacing spare parts
2.7 Measurement board
Service Manual SIPLACE MeasurementFeeder X 02/2020 25
2.7.1 Removing the measurement board
Remove the left side cover (see 2.4.1 "Removing
the side cover" [}15]).
Loosen the seven nuts marked in the figure using
a spanner size 5mm.
Disconnect to two connectors marked in the fig-
ure.
Remove the measurement board.
2 Replacing spare parts
2.7 Measurement board
26 Service Manual SIPLACE MeasurementFeeder X 02/2020
2.7.2 Fitting the measurement board
Align the measurement board to the Measure-
mentFeeder.
Put a drop of Loctite 243 on the top of every
single thread marked in the figure right before
tightening the nut.
Tighten the seven nuts (M2 X2.5, 03008160-xx)
marked in the figure using a spanner size 5mm.
Connect to two connectors marked in the figure.
Fit the left side cover to the feeder (see 2.4.2 "Fit-
ting the side plate" [}16]).
3 Synchronization
Service Manual SIPLACE MeasurementFeeder X 02/2020 27
3 Synchronization
Required tools
Fig.7: SIPLACE XFeeder Verification System (XFVS), item no. 03126186-xx
Synchronizing the MeasurementFeederX
When the MeasurementFeederX is power up, the system will compare serial number of the
contact module to the information stored in the EEPROM of the measurement board. The
MeasurementFeederX will not be able to function if the information does not match.
After changing the contact board and/or the measurement board, the MeasurementFeederX must
be inserted to the SIPLACE XFeeder Verification System (XFVS) to do a synchronization.
For further information please refer to the user manual of the X Feeder Verification System
(itemno. 00198272-XX).