00198532-01_SM_MeasurementFeeder_EN - 第28页
3 Synchronization 28 Service Manual SIPLACE MeasurementFeeder X 02/2020

3 Synchronization
Service Manual SIPLACE MeasurementFeeder X 02/2020 27
3 Synchronization
Required tools
Fig.7: SIPLACE XFeeder Verification System (XFVS), item no. 03126186-xx
Synchronizing the MeasurementFeederX
When the MeasurementFeederX is power up, the system will compare serial number of the
contact module to the information stored in the EEPROM of the measurement board. The
MeasurementFeederX will not be able to function if the information does not match.
After changing the contact board and/or the measurement board, the MeasurementFeederX must
be inserted to the SIPLACE XFeeder Verification System (XFVS) to do a synchronization.
For further information please refer to the user manual of the X Feeder Verification System
(itemno. 00198272-XX).

3 Synchronization
28 Service Manual SIPLACE MeasurementFeeder X 02/2020