6 Restrictions
● The evaluation of the entire SIPLACE line is incorrect if the line is equipped with a productivity
lift. The evaluation of individual SIPLACE machines is not affected by this.
● If the Monitoring Service is not compatible with the SIPLACE Pro server version (e.g. OIS 5.x
with SIPLACE Pro <4.1), it is not possible to import the line configuration from SIPLACE Pro.
The line configuration from SIPLACE Pro cannot be read by the OIS Line Config tool. You
must configure the lines manually (for description, see the online help of the OIS Line Config
tool).
● OIS Server has been tested with a maximum of 50 placement machines with station software
versions up to 605 and a maximum of 10 placement machines with station software versions
70x.
● On platform 1 machines the OIS client is not started automatically when the station is booted.
● The "lGantry" column has been added to the OIS PICKUPERROR table. This column contains
the gantry number whereas the "ucHead" column refers to the head number on the gantry. For
stations with one gantry and station software < 701, that are equipped with two heads per
gantry, the assignment does not apply. For these stations the gantry number is always "1" and
the head number is recorded in the "lGantry" column.
● Build time is only supported by:
– Station software versions >= 704
– SIPLACE Pro version >= 8.0
– OIS and Monitoring Service >= 8.0
● The alternative components option requires a license in SIPLACE Pro and is only supported
by:
– Station software versions >= 705
– SIPLACE Pro version >= 9.x
● The reporting functionality has been removed from the OIS Client.
– The OIS Report Viewer substitute tool is available in German only and has limited
formatting possibilities.
– No support for line-based reports.
OIS 10.1 / Software Version Description Ausgabe 11/2012 Edition
13
Monitoring functionality:
● 2.5 OIB Monitoring Clients only receive live data. Historic data cannot be queried.
● Consumption quantities follow the data sent by the stations:
– Pick-up errors on an empty track are considered as consumption
– Disposed components on fiducial error or station error are not contained in the consumption
data
● The Monitoring Service is only available with OIS versions >= 7.1.
● The Monitoring Service is only supported by SIPLACE Pro versions >= 7.0.
● The alternative components option requires a license in SIPLACE Pro and is only supported
by:
– Station software versions >= 705