2-33 AKOEMT -ID (08 Screen Eecognition Camera X Axi ) T able 4B24 Error ID Error Name, Description, Cause, and Remedy 0801000 Screen Rcg. Camera X Origin Zeroing opn. was incompleted, within specified time. (Cause 1) Dirt…

2-32 AKOEMT-ID
Table 4B23
Error ID Error Name, Description, Cause, and Remedy
0711000 PEC Rcg. Camera Y Interlock
PCB stopper was down.
(Cause 1) The PEC recognition Y
axis was activated after the PCB stopper had moved
down.
(Cause 2) The PCB stopper upper limit (B70) is defective.
(Remedy 1) Move up the PCB stopper and restart the operation.
(Remedy 2)
Adjust the sensor position. If this operation does not reset the machine to its
normal condition, it is required to replace the sensor with a new one. Contact
our service personnel for details.
0712000 PEC Rcg. Camera Y Interlock
PCB warpage protection was down.
(Cause 1)
The PEC recognition Y axis was activated after the PCB warpage top holder had
moved down.
(Remedy 1) Move up the PCB warpage top holder and restart the operation.
0713000 PEC Rcg. Camera Y Interlock
Cleaning nozzle is up.
(Cause 1)
The cleaning nozzle lower limit sensor (B81) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The PEC recognition Y axis was activated after the cleaning nozzle had moved
up. (during the manual operation)
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
0714000 PEC Rcg. Camera Y
Timing
Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0716000 PEC Rcg. Camera Y Origin
Zeroing Opn. Not Complete.
(Cause 1)
The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0609-002
2.2 Troubleshooting after Error Display

2-33 AKOEMT-ID
(08 Screen Eecognition Camera X Axi) Table 4B24
Error ID Error Name, Description, Cause, and Remedy
0801000 Screen Rcg. Camera X Origin
Zeroing opn. was incompleted, within specified time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2)
The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero the screen recognition camera X axis
again.
(Remedy 2)
It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the screen recognition camera X axis. If this operation does
not reset the machine to its normal condition, the driver may be defective.
Contact our service personnel for details.
0802000 Screen Rcg. Camera X Origin
Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1)
Check for any obstacle around the screen recognition X axis and then perform
the zeroing operation. If this operation does not reset the machine to its
normal condition, contact our service personnel for details.
0805000 Screen Rcg. Camera X Driver
Driver alarm signal was detected.
0808000 Screen Rcg. Camera X Driver
Driver Over-Heat
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
0811000 Screen Rcg. Camera X
Timing
Task has not been completed unable to continue.
0812000 Screen Rcg. Camera X Data
The data was detected outside of the possible range.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0814000 Screen Rcg. Camera X Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0609-002
2.2 Troubleshooting after Error Display

2-34 AKOEMT-ID
(09 PCB Backup Axis) Table 4B25
Error ID Error Name, Description, Cause, and Remedy
0901000 PCB Backup Axis Origin
Zeroing opn. was incompleted, within specified time.
(Cause 1)
Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero the PCB backup axis again.
(Remedy 2)
It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the PCB backup axis. If this operation does not reset the
machine to its normal condition, the driver may be defective. Contact our
service personnel for details.
0902000 PCB Backup Axis Origin
Detect lost pulse error.
(Cause 1)
The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the PCB backup axis and then perform the
zeroing operation. If this operation does not reset the machine to its normal
condition, contact our service personnel for details.
0905000 PCB Backup
Axis Driver
Driver alarm signal was detected.
0908000 PCB Backup Axis Driver
Driver Over-Heat
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
0911000 PCB Backup
Axis Timing
Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again.
After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0912000 PCB Backup Axis Data
The data was detected outside of the possible range.
(Cause 1)
The specified data may have exceeded the movable range.
(Remedy 1) Check the parameter in the “PCB Chuck Height” text box (“OFFSET
DATA”
window).
0913000 PCB Backup
Axis Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0609-002