2-38 AKOEMT -ID (1 1 Input Conveyor) T able 4B29 Error ID Error Name, Description, Cause, and Remedy 1 101000 Input Conveyor Width Origin Zeroing opn. was incompleted, within specified time. (Cause 1) Dirt adheres to the …

2-37 AKOEMT-ID
Table 4B28
Error ID Error Name, Description, Cause, and Remedy
1017000 Table Chute Width Interlock
Table-X
Axis interlock signal is OFF.
(Cause 1) The table X-axis interlock sensors (B4E and B4F) are defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The chute width was activated when the table X axis was brought close to the
right or the left. (during the manual operation)
(Remedy 1) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
1018000 Table Chute Width Data
The data was detected outside of the possible range.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1019000 Table Chute Width Origin
Zeroing Opn. Not Complete.
(Cause 1)
The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0609-002
2.2 Troubleshooting after Error Display

2-38 AKOEMT-ID
(11 Input Conveyor) Table 4B29
Error ID Error Name, Description, Cause, and Remedy
1101000 Input Conveyor Width Origin
Zeroing opn. was incompleted, within specified time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2)
The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off the dirt on the sensor and zero the origin of the input conveyor width
axis again.
(Remedy 2)
It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the origin of the input conveyor width axis. If this operation
does not reset the machine to its normal condition, the driver may be
defective. Contact our service personnel for details.
1102000 Input Conveyor Width Origin
Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1)
Check for any obstacle around the input conveyor width axis and perform the
zeroing operation. If this operation does not reset the machine to its normal
condition, contact our service personnel for details.
1105000 Input Conveyor Width Driver
Driver alarm signal was detected.
1108000 Input Conveyor Width Driver
Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
1110000
Input Conveyor Width Interlock
The distance Table-X axis and inp.conv
. exceeded min.limit
(Cause 1) The table X-axis interlock sensors (B4E and B4F) are defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The conveyor width was activated when the table X axis was brought close to
the right or the left. (during the manual operation)
(Remedy 1) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
0609-002
2.2 Troubleshooting after Error Display

2-39 AKOEMT-ID
Table 4B30
Error ID Error Name, Description, Cause, and Remedy
1111000 Input Conveyor Width Interlock
PCB was exist on conveyor.
(Cause 1) No operation is possible because a PCB still exists on the conveyor.
(Cause 2)
The PCB detection sensors (B40 and B41) are defective.
(Remedy 1) Remove the PCB and restart the operation.
(Remedy 2) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
1112000
Input Conveyor Width Data
The data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1
113000
Input Conveyor Width Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0609-002
2.2 Troubleshooting after Error Display